2012
DOI: 10.1016/j.prro.2012.03.012
|View full text |Cite
|
Sign up to set email alerts
|

Target volume changes through high-dose-rate brachytherapy for cervical cancer when evaluated on high resolution (3.0 Tesla) magnetic resonance imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
1

Relationship

5
3

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 27 publications
0
8
0
Order By: Relevance
“…Orthogonal radiographs using a C-arm were taken before and after each MRI scan (Pre- and Post-X-ray). The institutional protocols for external beam radiotherapy and HDR BT fractionation schemes were detailed in previous studies [ 7 , 20 22 ]. High-risk clinical target volumes (HR-CTV), of the rectum, bladder, and sigmoid were retrospectively delineated as per GEC-ESTRO recommendations [ 2 , 3 ].…”
Section: Methodsmentioning
confidence: 99%
“…Orthogonal radiographs using a C-arm were taken before and after each MRI scan (Pre- and Post-X-ray). The institutional protocols for external beam radiotherapy and HDR BT fractionation schemes were detailed in previous studies [ 7 , 20 22 ]. High-risk clinical target volumes (HR-CTV), of the rectum, bladder, and sigmoid were retrospectively delineated as per GEC-ESTRO recommendations [ 2 , 3 ].…”
Section: Methodsmentioning
confidence: 99%
“…A T&O applicator was reconstructed (digitized) on T1‐weighted MR images 6. The details of the HDR workflow, imaging, and planning have been previously described 21, 22, 23, 24…”
Section: Methodsmentioning
confidence: 99%
“…6 The details of the HDR workflow, imaging, and planning have been previously described. [21][22][23][24] An adaptive/conformal volume optimization HDR plan was retrospectively created for each clinical Point A plan through a hybrid-inverse optimization process that includes a combination of an inverse optimization and manual forward planning. The hybridinverse optimization process 21,22,25,26 5,7 and the ICRU Report #89.…”
Section: A | Ebrt and 3t Mri-guided Adaptive/conformal Volume Optimentioning
confidence: 99%
“…Three Tesla (3T) MRI‐guided, titanium T&O HDR BT volume optimization planning is institutional standard care 23 , 24 , 25 , 26 . We validated the artifacts and distortions of titanium in the high 3T magnetic field (23) in order to use the 3T MRI as a single planning imaging modality for MRI‐guided GYN BT.…”
Section: Methodsmentioning
confidence: 99%