2000
DOI: 10.1016/s0958-3947(00)00049-2
|View full text |Cite
|
Sign up to set email alerts
|

TBI treatment planning using the ADAC Pinnacle Treatment Planning System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
19
0

Year Published

2007
2007
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(19 citation statements)
references
References 3 publications
0
19
0
Order By: Relevance
“…Plans calculated in the Pinnacle TPS using a standard beam model have shown good agreement with doses measured in phantom, including modeling of lung shielding by arms, complex aluminum compensators or MLC blocking of head and lung 12 , 13 . Lavallée et al (14) found improved accuracy with a specific TBI beam model, but this was mainly in the area of out‐of‐field dose, which was significant for the AP/PA field translating couch technique being used.…”
Section: Discussionmentioning
confidence: 81%
See 1 more Smart Citation
“…Plans calculated in the Pinnacle TPS using a standard beam model have shown good agreement with doses measured in phantom, including modeling of lung shielding by arms, complex aluminum compensators or MLC blocking of head and lung 12 , 13 . Lavallée et al (14) found improved accuracy with a specific TBI beam model, but this was mainly in the area of out‐of‐field dose, which was significant for the AP/PA field translating couch technique being used.…”
Section: Discussionmentioning
confidence: 81%
“…More recently, treatment planning using computed tomography (CT) scans of the patient have been introduced, using either in‐house (9) or commercial software 10 , 11 , 12 , 13 , 14 . CT data allow accurate estimation of organ‐at‐risk doses such as the lung, which usually limits the maximum tolerable dose.…”
Section: Introductionmentioning
confidence: 99%
“…In the last decade, however, a number of studies have demonstrated the use of commercially available treatment planning systems for TBI dose distribution calculations. ( 1 5 ) These studies were based on either standard or modified models using data acquired under TBI conditions (i.e. at extended SSD).…”
Section: Introductionmentioning
confidence: 99%
“…This technique, along with chemotherapy, is most often utilized to treat myeloid and lymphoid disease by providing conditioning for bone marrow transplant (2) . Radiation results in immunosuppression and also eradicates a modest number of radiosensitive tumor cells, clearing the host marrow to allow repopulation with donor marrow cells (3) .…”
Section: Introductionmentioning
confidence: 99%
“…Other studies have explored this subject utilizing the AAA and ADAC Pinnacle (Philips Healthcare, Andover, MA) albeit at much shorter SSDs of less than 180 cm 2 , 13 . This study is unique in that two commissioned dose calculation algorithms are compared to measurements at an extended SSD of 400 cm.…”
Section: Introductionmentioning
confidence: 99%