2013
DOI: 10.1016/j.jtos.2013.04.004
|View full text |Cite
|
Sign up to set email alerts
|

Tear Fluid Biomarker Profiling: A Review of Multiplex Bead Analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
42
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
2

Relationship

2
7

Authors

Journals

citations
Cited by 48 publications
(42 citation statements)
references
References 91 publications
0
42
0
Order By: Relevance
“…4547 Inflammatory mediators released in tears have been recognized as one of the key components in ocular surface inflammation that have prominent roles in the pathophysiology of DED. 48 Of the multiple inflammatory biomarkers under investigation, cytokines and chemokines are the most frequently reported and studied in DED.…”
Section: Biomarkers Of Inflammationmentioning
confidence: 99%
“…4547 Inflammatory mediators released in tears have been recognized as one of the key components in ocular surface inflammation that have prominent roles in the pathophysiology of DED. 48 Of the multiple inflammatory biomarkers under investigation, cytokines and chemokines are the most frequently reported and studied in DED.…”
Section: Biomarkers Of Inflammationmentioning
confidence: 99%
“…Therefore future studies, including the optimization of standard operating procedures for qPCR, should first be undertaken in order to address this potentially confounding factor. As with tear fluid biomarker analysis [72], it is anticipated that future IC studies comprising larger patient cohorts, more strict stratification of recruited patients, improved assay sensitivities and standardized methodologies will all serve to enhance the diagnosis, monitoring and treatment of disorders of the ocular surface.…”
Section: Resultsmentioning
confidence: 99%
“…This single-use silicone contact lens is a noninvasive wireless contact lens sensor capable of automatically recording IOP changes for up to 24 h. 11,46,47 The technology uses four circular strain gauges embedded within the contact lens, which are capable of sensing circumferential changes at the limbus. 11,13,14,16,48 Relative variations in IOP can thus be monitored indirectly by virtue of the changes in ocular volume they cause. 11,46,47 The embedded microprocessor and antenna in the contact lens sensor transfer the data wirelessly to an external eyepiece.…”
Section: Semicontinuous Iop Monitoring For Glaucomamentioning
confidence: 99%
“…12Y14 One of the biggest advantages of developing contact lens sensors is it provides a noninvasive alternative to current invasive methods to monitor diseases. 15,16 This overview will highlight the major progress to date in developing contact lens sensors for continuous, semicontinuous, and noncontinuous detection of diseases and several of the key technical and clinical challenges in this field as reported in the peer-reviewed literature. Because of space considerations, although we have extensively discussed peer-reviewed publications, it has not been possible to take into consideration the entire patent literature in this area, which is extensive.…”
mentioning
confidence: 99%