Tear fluid collection in dogs and cats using ophthalmic sponges

Abstract: Polyvinyl acetal is better than cellulose for tear collection given its superior recovery. Ophthalmic sponges could facilitate routine analysis of tear fluid in dogs and cats, although further studies are needed to evaluate the quality of tears obtained with this method.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
36
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 24 publications
(36 citation statements)
references
References 27 publications
0
36
0
Order By: Relevance
“…Strips were left until the ≥20-mm mark was reached, followed by centrifugation for 2 minutes at 3884 g in a punctured 0.2-mL tube (secured to 2-mL tube) to extract tear fluid for the ferning test. 22 • Tear ferning test: For each sample, 2 µL of tear fluid was deposited on a glass slide inside a 2-mm circular area delineated with a marking pen. Following air drying at room temperature for 10 minutes, 23 each sample was examined with light microscopy (10 X magnification) and classified as grade 1, grade 2, grade 3, or grade 4 according to specific criteria described by Oria and colleagues.…”
Section: Methodsmentioning
confidence: 99%
“…Strips were left until the ≥20-mm mark was reached, followed by centrifugation for 2 minutes at 3884 g in a punctured 0.2-mL tube (secured to 2-mL tube) to extract tear fluid for the ferning test. 22 • Tear ferning test: For each sample, 2 µL of tear fluid was deposited on a glass slide inside a 2-mm circular area delineated with a marking pen. Following air drying at room temperature for 10 minutes, 23 each sample was examined with light microscopy (10 X magnification) and classified as grade 1, grade 2, grade 3, or grade 4 according to specific criteria described by Oria and colleagues.…”
Section: Methodsmentioning
confidence: 99%
“…244,260,261 For instance, Schirmer strips were used for indepth characterization of proteomics in human 173 and canine tears, 190 and can also successfully recover specific analytes such as cytokines, 200,258 clusterin, 182 and xenobiotics. 211,[213][214][215]244,262 Absorbent sponges exist in different material types such as cellulose, 234,236,263,264 polyvinyl acetal, 209,214,228,236,244,264-266 polyester, 239,242,266 and polyrurethane. 236 A material with hydrophilic and hydrophobic properties (e.g., polyvinyl acetal and polyurethane) 236,264 is generally preferred to optimize the amount of fluid absorbed and the amount of fluid retrieved from the sponge.…”
Section: Indirect Tear Samplingmentioning
confidence: 99%
“…211,[213][214][215]244,262 Absorbent sponges exist in different material types such as cellulose, 234,236,263,264 polyvinyl acetal, 209,214,228,236,244,264-266 polyester, 239,242,266 and polyrurethane. 236 A material with hydrophilic and hydrophobic properties (e.g., polyvinyl acetal and polyurethane) 236,264 is generally preferred to optimize the amount of fluid absorbed and the amount of fluid retrieved from the sponge. For tear fluid collection, the sponge is held against the lacrimal lake by the operator (to minimize reflex tearing), 234,239,242,244,266 or placed beneath the lower eyelid for a given period of time.…”
Section: Indirect Tear Samplingmentioning
confidence: 99%
See 2 more Smart Citations