Temporary extracorporeal left ventricular support with transapical ProtekDuo cannula

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 3 publications
0
8
0
Order By: Relevance
“… 9 Therefore, it was necessary to reconsider and use the ProtekDuo RVAD plus oxygenator to provide oxygenated blood to the patient as well as RV offloading by bypassing the RV. The ProtekDuo is a multi-purpose cannula that has been used and described in several different settings, such as for RVAD, 10 LVAD, 11 , 12 BiVAD (ECPELLA 2.0), 12 , 13 ECMO, or cardiopulmonary bypass (CPB) 14 , 15 support. Default is the V-P configuration with blood drainage from the RA and blood return into the PA. An average blood flow of 4.5 LPM may be achieved.…”
Section: Discussionmentioning
confidence: 99%
“… 9 Therefore, it was necessary to reconsider and use the ProtekDuo RVAD plus oxygenator to provide oxygenated blood to the patient as well as RV offloading by bypassing the RV. The ProtekDuo is a multi-purpose cannula that has been used and described in several different settings, such as for RVAD, 10 LVAD, 11 , 12 BiVAD (ECPELLA 2.0), 12 , 13 ECMO, or cardiopulmonary bypass (CPB) 14 , 15 support. Default is the V-P configuration with blood drainage from the RA and blood return into the PA. An average blood flow of 4.5 LPM may be achieved.…”
Section: Discussionmentioning
confidence: 99%
“…With this flow, the aortic valve remained closed and the LV well decompressed. 11 Temporary left ventricular MCS is supposed to decompress the LV and provide adequate forward flow into the aorta and systemic circulation, as it can be achieved with endovascular devices like the Impella or ProtekDuo. In a report by Bellani et al, 12 the authors describe the successful transesophageal echocardiographyguided placement of a ProtekDuo RD via a left ventricular apical approach to provide minimally invasive LV support in a high-risk Jehovah's Witness patient.…”
Section: Protekduo As Lvad In Left Ventricular Failurementioning
confidence: 99%
“…Goodwin et al 11 reported ProtekDuo cannula insertion though the LV apex as described in the technique above to provide temporary left-sided support in a patient designated as INTERMACS profile 1. The cannula provided excellent hemodynamic support without hemolysis or insertion-site bleeding and allowed for end-organ recovery to bridge this patient to a durable LVAD (Figure 2(b)).…”
Section: Protekduo As Lvad In Left Ventricular Failurementioning
confidence: 99%
“…7 Moreover, there have been case reports describing the transapical insertion of a dual-lumen cannula for temporary paracorporeal LV support (Figure 1C). 8,9 At our institute, we develop an accessory for durable intracorporal LVADs. The accessory combines the inflow cannula and outflow graft (OG) in a dual-lumen adapter with a transventricular OC across the AV (Figure 1D).…”
Section: Introductionmentioning
confidence: 99%