Abstract:Undesirable vibration in pipeline structures due to internal gas/liquid coupling, mechanical vibration, and water hammer action may cause machine shutdown, leakage, fatigue failure, and sometimes catastrophic explosion. It is necessary to design a device to mitigate pipeline vibration. This paper proposes a new type of particle damper, the multi-cavity particle damper (MPD). A mechanical MPD model is first proposed. Second, the analytical solutions of the MPD are given for the case of two symmetric impacts per… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.