2021
DOI: 10.1002/lom3.10435
|View full text |Cite
|
Sign up to set email alerts
|

Testing miniaturized extraction chromatography protocols for combined 87Sr/86Sr and δ88/86Sr analyses of pore water by MC‐ICP‐MS

Abstract: We tested two miniaturized extraction chromatography protocols for strontium isolation based on 300 μL (Protocol 1) and 30 μL (Protocol 2) column volumes of Sr‐Spec resin, for the simultaneous determination of 87Sr/86Sr and δ88/86Sr by MC‐ICP‐MS. The accuracy and precision of the Sr isotope ratios have been evaluated by analyzing JCt‐1 and SRM 1640a reference materials, resulting in a reproducibility of 87Sr/86Sr and δ88/86Sr values of 0.000026 and 0.04‰ (Protocol 1) (2SD, n = 3), and of 0.000074 and 0.13‰ (Pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 50 publications
(111 reference statements)
0
5
0
Order By: Relevance
“…Bulk rock samples were digested in closed-PTFE vessels on the hotplate (150°C), using a mixture of concentrated HNO 3 , HCl and HF, until total dissolution. Waters were filtered (5 μm) and acidified with HNO 3 to a concentration of 3 M [ 90 ]. Plant samples were air-dried, ashed at 650° C and digested with concentrated suprapur HNO 3 [ 91 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Bulk rock samples were digested in closed-PTFE vessels on the hotplate (150°C), using a mixture of concentrated HNO 3 , HCl and HF, until total dissolution. Waters were filtered (5 μm) and acidified with HNO 3 to a concentration of 3 M [ 90 ]. Plant samples were air-dried, ashed at 650° C and digested with concentrated suprapur HNO 3 [ 91 ].…”
Section: Methodsmentioning
confidence: 99%
“…Strontium was purified in 30 μL-volume columns filled with Eichrom Sr spec–resin (100–150 μm bead size) as described in [ 90 ]. Sr was eluted with MilliQ water and collected in clean polypropylene vials.…”
Section: Methodsmentioning
confidence: 99%
“…5 mg of enamel (n = 38) were digested with suprapur nitric acid and processed through ion exchange chromatography. Sr was separated using 30 μl columns [127] filled with Eichrom Sr-spec resin. The 87 Sr/ 86 Sr ratio was determined with a Neptune MC-ICPMS housed at the Centro Interdipartimentale Grandi Strumenti (UNIMORE).…”
Section: Strontium Isotopesmentioning
confidence: 99%
“…About 5 mg of bioapatite powder for each sample was dissolved in 3M HNO 3 . The Sr separation from the matrix was performed through chromatographic Teflon columns filled with 30 μl of Eichrom Sr spec resin [ 121 , 122 ]. Once the columns were cleaned with MilliQ, the dissolved samples were loaded and the cations (not Sr) were desorbed by percolating 3M HNO 3 , to eliminate matrix ions.…”
Section: Methodsmentioning
confidence: 99%