“…Very low limits for a violation of PEP of <10 −21 and <10 −14 were found for non-Paulian 20 Ne in normal 20 Ne and for non-Paulian 5 Li in Lithium, respectively. A test of non-Paulian beryllium with all four electrons in the K shell (helium-like atoms) was performed with AMS by the PRIME Lab of Purdue University [107]. No non-Paulian Be events were observed and stringent concentration limits were set for a variety of materials investigated.…”
Section: Testing the Pauli Exclusion Principlementioning
confidence: 99%
“…Very low limits for a violation of PEP of <10 −21 and <10 −14 were found for non-Paulian 20 Ne in normal 20 Ne and for non-Paulian 5 Li in Lithium, respectively. A test of non-Paulian beryllium with all four electrons in the K shell (helium-like atoms) was performed with AMS by the PRIME Lab of Purdue University [107]. No non-Paulian Be events were observed and stringent concentration limits were set for a variety of materials investigated.…”
Section: Testing the Pauli Exclusion Principlementioning
confidence: 99%
“…Routine performance was almost as good as that obtained when biochemical samples were analysed using a 10 MV AMS system. A compact instrument, originally designed for radiocarbon analysis, has been tested for the determination of other radionuclides, in particular 26 Al and 10 Be. 21 Although yields of these isotopes were similar to those obtained with higher energy systems, problems of high background levels remained to be addressed.…”
Section: Instrumentationmentioning
confidence: 99%
“…A new gas introduction system was found necessary in order to increase the efficiency of conversion of Be to BeO 2 for AMS analysis. 26 A specially designed cathode allowed the gas to enter the ion source directly adjacent to the oxide surface (Sm 2 O 3 or Yb 2 O 3 ) needed to create the BeO 2 beam. Six holes were drilled around the rim of the cathode and the oxide packed in the area just beside the holes.…”
Section: Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…Although the principle has been spectacularly confirmed by the number and accuracy of its predictions, it remains somewhat mysterious, and, given its basic standing in quantum theory, it is appropriate to carry out precise tests of its validity. Indeed, mostly in the last 15-20 years, several experiments have searched for possible small violations [3][4][5][6][7][8][9][10]. Quite often, these searches originated as by-products of experiments dedicated to different kinds of physics (like, e.g., dark matter searches, proton decay, etc.…”
Section: Introductionmentioning
confidence: 99%