TH‐C‐M100E‐04: Cerenkov Light From Phantom Cassettes in Absolute Dose Measurements Using Radiographic Film

Abstract: Purpose: To determine the impact of Cerenkov light on radiographic film response and to recommend a methodology for correcting absolute dose measurements when using bare film, but calibrated using prepackaged film. Method and Materials: The Gammex RMI Film Dosimetry Cassette Model 436‐AST (Solid Water) and two in‐house cassettes (white opaque, high‐impact polystyrene) were studied using Kodak XV or EDR2 film. Films were exposed perpendicular to 16‐MeV electron (15×15 cm2) or 6 MV x‐ray (20×20 cm2) beams. Films… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2008
2008
2008
2008

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…In order to determine the relative contribution of Cerenkov radiation to the bare film darkening, 14 a method similar to Perrin et al's work was utilized. 15 EDR2 film was inserted into the sagittal film cassette, which was placed on the flat treatment couch of a Varian Clinac 21EX linac, on top of 10 cm of Plastic Water® backscatter material. One film ͑No.…”
Section: Iid2 Correction For Cerenkov Radiationmentioning
confidence: 99%
“…In order to determine the relative contribution of Cerenkov radiation to the bare film darkening, 14 a method similar to Perrin et al's work was utilized. 15 EDR2 film was inserted into the sagittal film cassette, which was placed on the flat treatment couch of a Varian Clinac 21EX linac, on top of 10 cm of Plastic Water® backscatter material. One film ͑No.…”
Section: Iid2 Correction For Cerenkov Radiationmentioning
confidence: 99%
“…As some Cerenkov light is produced in the white paper, keeping the readypack sleeve over the film also maintained the same irradiation conditions as the calibration film, ensuring proper calibration. 10,11 Each calibration curve ͑dose versus intensity͒ consisted of ten points, values at the center of each of the eight squares, a point at the center of the calibration film ͑scatter dose contribution͒, and a zero-dose point from the background film. A piecewise polynomial curve in RIT software was fit to the data points.…”
Section: Iie Film Dosimetry Systemmentioning
confidence: 99%