1964
DOI: 10.6028/jres.068a.053
|View full text |Cite
|
Sign up to set email alerts
|

The 1962 He3 scale of temperatures. II. Derivation

Abstract: An Experimental ThermodYlllLmic ]~quation (ETE) temperature scale valid from 0.2 to 2.0 oK has been calculated for JIe 3 . The scale is based on new compariso Jl s, (P" p.), of Ile3 a nd He' vapor pressures above 0.9 oK; on the 1958 lIe' temperature scale; and on the best available data for several thermodynamic properties of Ile 3 from 0.2 to 2.0 oK.The '1'62 Full-Ran ge Working Equation (F WE) scale,In P 3=-2.49174/ 7' + 4.80386 -0.286001 7' + 0.198608 1'2 -0.0502237 1'3+ 0.00505486 T' + 2.24846 In T fits t … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
10
0

Year Published

1969
1969
2016
2016

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(11 citation statements)
references
References 9 publications
1
10
0
Order By: Relevance
“…If T^g is in error, then 's also since the latter scale.is based upon comparisons (4) between the vapor 3 4 pressures of He and He . Nevertheless, both of these scales are smooth and thermodynamically consistent internally (5,6,10,11,12) the present data appears in Appendix B, and previously published (14) calibration data on two GER's used in this work are given In Appendix C.…”
Section: The Intermediate Regionsupporting
confidence: 81%
See 3 more Smart Citations
“…If T^g is in error, then 's also since the latter scale.is based upon comparisons (4) between the vapor 3 4 pressures of He and He . Nevertheless, both of these scales are smooth and thermodynamically consistent internally (5,6,10,11,12) the present data appears in Appendix B, and previously published (14) calibration data on two GER's used in this work are given In Appendix C.…”
Section: The Intermediate Regionsupporting
confidence: 81%
“…The Helium region 4 3 Recently the accuracies of the current He and He vapor pressure scales, T^g (3) and T^g (7), respectively, have been questioned (9). 4 Acoustic data (16) indicate that the T^g value for the He boiling point is 10 mK too low, while a difference of T-T^g of 8 + 3 mK at 4.2 K was observed by RTAS (14) from CVGT data.…”
Section: The Intermediate Regionmentioning
confidence: 99%
See 2 more Smart Citations
“…In the history of international temperature scales, which started in 1887 when the first international temperature scale was adopted by the Comité International des Poids et Mesures (CIPM), only four different truly low-temperature scales were adopted, namely the 1958 4 He and 1962 3 He vapour-pressure scales [5,6], the 1976 Provisional 0.5 K to 30 K Temperature Scale (EPT-76) [7] and the PLTS-2000 [2]. The ITS-90 is basically identical to the EPT-76 in the temperature range between 0.65 K and 5 K as it is based on the same experimental dataset for the helium vapour pressure but is represented in a different mathematical form.…”
Section: Introductionmentioning