2013
DOI: 10.1016/j.nimb.2012.06.024
|View full text |Cite
|
Sign up to set email alerts
|

The 1MV multi-element AMS system for biomedical applications at the Netherlands Organization for Applied Scientific Research (TNO)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…A final CO 2 /helium mixture of 6% was directed to the AMS ion source, at a pressure of 1 bar and a flow of 60 µL/minute. A 1‐MV Tandetron AMS (High Voltage Engineering Europe B.V., Amersfoort, The Netherlands) 33 was used. To determine the true amount of radioactivity in each fraction, the measured [ 14 C]/[ 12 C] ratios were multiplied by the corresponding total carbon measurement of the elemental analyzer.…”
Section: Methodsmentioning
confidence: 99%
“…A final CO 2 /helium mixture of 6% was directed to the AMS ion source, at a pressure of 1 bar and a flow of 60 µL/minute. A 1‐MV Tandetron AMS (High Voltage Engineering Europe B.V., Amersfoort, The Netherlands) 33 was used. To determine the true amount of radioactivity in each fraction, the measured [ 14 C]/[ 12 C] ratios were multiplied by the corresponding total carbon measurement of the elemental analyzer.…”
Section: Methodsmentioning
confidence: 99%
“…A final CO 2 /helium mixture of 6% was directed to the AMS ion source, at a pressure of 1 bar and a flow of 60 µL/min. A 1-MV Tandetron AMS (High Voltage Engineering Europe B.V., Amersfoort, The Netherlands) [ 27 ] was used. The lower limit of quantification (LLOQ) of the method was 0.58 Bq/L.…”
Section: Methodsmentioning
confidence: 99%
“…CO 2 was released by heating of the trap and transferred to a vacuum syringe using helium. The resulting 6% v/v gas mixture of CO 2 with helium was infused at a pressure of 1 bar at 60 μL/min into the titanium target in the SO110 ion source of a 1 MV Tandetron AMS (High Voltage Engineering Europe B.V., The Netherlands) . As the AMS solely counts [ 14 C] atoms, the analysis is universal.…”
Section: Methodsmentioning
confidence: 99%
“…The resulting 6% v/v gas mixture of CO 2 with helium was infused at a pressure of 1 bar at 60 lL/min into the titanium target in the SO110 ion source of a 1 MV Tandetron AMS (High Voltage Engineering Europe B.V., The Netherlands). 28,29 As the AMS solely counts [ 14 C] atoms, the analysis is universal. No study, matrix, or compound method development is required.…”
Section: Determination Of Enzymatic Activitymentioning
confidence: 99%