2012
DOI: 10.1016/j.yrtph.2012.06.001
|View full text |Cite
|
Sign up to set email alerts
|

The 3T3 neutral red uptake phototoxicity test: Practical experience and implications for phototoxicity testing – The report of an ECVAM–EFPIA workshop

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
25
0
3

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 79 publications
(28 citation statements)
references
References 10 publications
0
25
0
3
Order By: Relevance
“…Final considerations. The tiered strategy recommended by OECD (2004) guideline and subsequent papers (Ceridono et al, 2012;Jírova et al, 2005;Kejlová et al, 2007) include 3T3 as the first test to be performed in the evaluation of phototoxicity in compounds. A negative 3T3 NRU-PT result is regarded as a sufficient stand-alone indicator for photosafety, while a positive one always requires further considerations and testing.…”
Section: Phototoxicity and Photoallergy Evaluationsmentioning
confidence: 99%
“…Final considerations. The tiered strategy recommended by OECD (2004) guideline and subsequent papers (Ceridono et al, 2012;Jírova et al, 2005;Kejlová et al, 2007) include 3T3 as the first test to be performed in the evaluation of phototoxicity in compounds. A negative 3T3 NRU-PT result is regarded as a sufficient stand-alone indicator for photosafety, while a positive one always requires further considerations and testing.…”
Section: Phototoxicity and Photoallergy Evaluationsmentioning
confidence: 99%
“…Given that false negatives are particularly infrequent when using this method, it can be considered suitable for the evaluation of phototoxicity. One application of 3T3 NRU PT testing is the evaluation of poorly water-soluble substances, for which an alternative method, a 3-dimensional cultured skin model, has also been proposed (Ceridono et al, 2012;Portes et al, 2002;Netzaff et al, 2005). Since 3T3 NRU PT can characteristically identify phototoxicological hazards with almost 100% specificity, it can be considered highly economical and easier to use than the 3-dimensional cultured skin model and was therefore used in this study to evaluate poorly water-soluble substances.…”
Section: Discussionmentioning
confidence: 99%
“…RhE modellerinin, topikal olarak uygulanan kimyasal maddelerin fototoksik tehlikelerinin belirlenmesinde güvenilir bir şekilde kullanılabileceği ileri sürülmektedir. Bu doku modelleri 3T3 NRU testinin alternatifi olarak veya 3T3 NRU testinin hatalı pozitif sonuçlarının sayısını azaltmak amacıyla pozitif sonuçların doğrulanması için bir ara kademe test olarak kullanılabilir (55).…”
Section: In Vitro Insan 3d Epidermis Modeliunclassified
“…3T3 NRU testinde pozitif sonuç veren iki örnek ve in vivo testte negatif sonuç veren bir örnek RhE model üzerinde denenmiş ve doğru sonuçlar elde edilmiştir (55). Örneğin, bergamot yağı topikal olarak uygulanan bir bitkisel bir üründür.…”
Section: In Vitro Insan 3d Epidermis Modeliunclassified