2007
DOI: 10.1016/j.seppur.2006.12.019
|View full text |Cite
|
Sign up to set email alerts
|

The development and performance evaluation of a cyclone train for the removal of contaminated hot particulate in a hot cell

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 15 publications
0
4
0
1
Order By: Relevance
“…The considered models can approximately predict this region. Another parameter affecting cyclone efficiency is the vortex finder length (Figure 7) Experimental data (Hsiao et al [16]; Kim et al [10]; Zhu and Lee [12]) were used to deter mine the prediction efficiency of the models. Looking at the experimental results from these studies, the critical diameter generally increases up to a specific value with increas ing s value, and then decreases.…”
Section: Effect Of Vortex Finder Diameter and Lengthmentioning
confidence: 99%
See 2 more Smart Citations
“…The considered models can approximately predict this region. Another parameter affecting cyclone efficiency is the vortex finder length (Figure 7) Experimental data (Hsiao et al [16]; Kim et al [10]; Zhu and Lee [12]) were used to deter mine the prediction efficiency of the models. Looking at the experimental results from these studies, the critical diameter generally increases up to a specific value with increas ing s value, and then decreases.…”
Section: Effect Of Vortex Finder Diameter and Lengthmentioning
confidence: 99%
“…Iozia and Leith [9] conducted experimental studies at different inlet velocities in a cyclone with a diameter of 250 mm. Kim et al [10] stated that, for a cyclone separator with a diameter of 76 mm, at different inlet velocities, the best efficiency for the cyclones in their experimental studies was at an inlet velocity of 15 m/s. Moore and McFarland [11] conducted experimental studies on cyclone separators with four different diameters, while Zhu and Lee [12] considered cyclone separators with different geometries and a diameter of 30.5 mm at different inlet velocities.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[73], and the agglomeration of fine particles was observed at the initial stages. Ahuja et al [74] and Kim et al [75] reported that the collection efficiency of fine particles increases substantially with humidity. However, few studies have investigated the effects of dust particle properties, such as particle humidity, particle temperature, and classification, through experimental and numerical simulations.…”
Section: The Performance Of Cyclone Separators Under Varying Particle...mentioning
confidence: 99%
“…Iozia & Leith, (1990), 250 mm çapı olan bir siklonda farklı giriş hızlarında deneysel çalışmalar yapmışlardır [7]. G. N. Kim, Choi, & Jung, (2007) 76mm çapa sahip siklon ayırıcı için farklı giriş hızlarında yaptıkları deneysel çalışmalarında çalıştıkları siklonlar için en iyi verimi 15m/s giriş hızı için gerçekleştiğini belirtmişlerdir [8]. Moore & McFarland, (1990) dört farklı çapa sahip siklon ayırıcı için, Zhu & Lee, (1999) ise 30,5mm çapa sahip farklı geometrilerdeki siklon ayırıcıları için farklı giriş hızlarında deneysel çalışmalar gerçekleştirmişlerdir [9,10].…”
unclassified