2016
DOI: 10.1039/c6ay01856d
|View full text |Cite
|
Sign up to set email alerts
|

The development of a matrix metalloproteinase-1 biosensor based on the surface plasmon resonance imaging technique

Abstract: The purpose of this study was to create a new, highly selective biosensor, which uses surface plasmon resonance as a detection method for the quantitative determination of the matrix metalloproteinase-1.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
34
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 32 publications
(34 citation statements)
references
References 19 publications
0
34
0
Order By: Relevance
“…As interferents, human albumin, MMP-1, MMP-2, cathepsin B, cathepsin D, cathepsin E, and cathepsin G were used. The choice of these interferents was made because of the fact that albumin is the most common protein in human body fluids [21]; MMP-1, MMP-2, as the CTSL, which are proteases, take part in the degradation of the extracellular proteins [17]; cathepsin B, D, E, G are compounds belonging to the cathepsin group as the cathepsin L.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…As interferents, human albumin, MMP-1, MMP-2, cathepsin B, cathepsin D, cathepsin E, and cathepsin G were used. The choice of these interferents was made because of the fact that albumin is the most common protein in human body fluids [21]; MMP-1, MMP-2, as the CTSL, which are proteases, take part in the degradation of the extracellular proteins [17]; cathepsin B, D, E, G are compounds belonging to the cathepsin group as the cathepsin L.…”
Section: Resultsmentioning
confidence: 99%
“…During the quantitative determination of the different proteins by the SPRI technique two, different types of an immobilization are used: antibody—antigen (covalent type of the immobilization, e.g., [17]) or inhibitor—enzyme (hydrophobic type of the immobilization, e.g., [18]). For the quantification of the CTSL, the enzyme—inhibitor (RKLLW-NH 2 ) interaction was used.…”
Section: Introductionmentioning
confidence: 99%
“…Current interest in MMPs and fibronectin in saliva suggested the necessity for further investigations. Therefore, in our study we wanted to investigate the levels of MMP-1, MMP-2 and fibronectin in the saliva of patients with caries, planned for endodontic treatment or surgical extraction using the Surface Plasmon Resonance (SPR) imaging method [25][26][27][28].…”
Section: Fibronectinmentioning
confidence: 99%
“…The papers pertaining to stages (iii) and (iv) represent complete analytical procedures [14,15,16,17,18,19,20,21,22,23,24,25,26,27]. These biosensors and related analytical procedures are ready to be subjected to clinical investigation for subsequent use in diagnosis.…”
Section: Stages Of Biosensor Developmentmentioning
confidence: 99%
“…Example of covalent antibody immobilization ( c ) and picture of the chip ( a ) and image of the chip obtained by a CCD camera ( b ). Reproduced from [22] with permission of Royal Society of Chemistry.…”
Section: Figurementioning
confidence: 99%