2008
DOI: 10.1016/j.jcrysgro.2007.10.075
|View full text |Cite
|
Sign up to set email alerts
|

The effect of co-doping on the growth stability and scintillation properties of lutetium oxyorthosilicate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
30
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 45 publications
(32 citation statements)
references
References 11 publications
(12 reference statements)
2
30
0
Order By: Relevance
“…[ 47,48 ] The quantum effi ciency (QE) calibration of the HPMT allowed us to evaluate the LY values from N phels ( E ) photoelectron yields even in the green spectral range where QEs are below 10%; the error of the LY values was ± 5%. The N phels ( E ) values were measured from 8 to 1300 keV using different radioisotopes, such as 22 Co, etc. The scintillation decay curves were obtained using a Hamamatsu PMT U7600 (Hamamatsu Co., Japan) and digital oscilloscope (Tektronix TDS3052, Tektronix, Inc., USA) under excitation by 511 keV photons from a 22 Na source.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…[ 47,48 ] The quantum effi ciency (QE) calibration of the HPMT allowed us to evaluate the LY values from N phels ( E ) photoelectron yields even in the green spectral range where QEs are below 10%; the error of the LY values was ± 5%. The N phels ( E ) values were measured from 8 to 1300 keV using different radioisotopes, such as 22 Co, etc. The scintillation decay curves were obtained using a Hamamatsu PMT U7600 (Hamamatsu Co., Japan) and digital oscilloscope (Tektronix TDS3052, Tektronix, Inc., USA) under excitation by 511 keV photons from a 22 Na source.…”
Section: Methodsmentioning
confidence: 99%
“…The N phels ( E ) values were measured from 8 to 1300 keV using different radioisotopes, such as 22 Co, etc. The scintillation decay curves were obtained using a Hamamatsu PMT U7600 (Hamamatsu Co., Japan) and digital oscilloscope (Tektronix TDS3052, Tektronix, Inc., USA) under excitation by 511 keV photons from a 22 Na source. To enhance the collection of scintillation photons, a Tefl on refl ection tape was used to cover the samples.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In [18], the Ø32 × 100 mm almost independent on the type of the crystal structure that was formed [16].…”
Section: Growth Of Lumentioning
confidence: 99%
“…However, in some cases [17,18] This shortcoming was suppressed by incorporation of additional compensating co-dopant of Zn into the structure.…”
Section: Growth Of Lumentioning
confidence: 99%