The evaluation of the insulation performances of the stator coil for the high power vertical synchronous hydro-generators by monitoring the level of partial discharges

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…Some studies use the maximum amplitude of 1000 pC as a reference to indicate PD activity in medium voltage machines, this threshold being based on international standards [42]. To verify this value, in [42], tests were realized in a hydro generator, where voltages of 7, 9, 10.5, and 11 kV were applied to the machine terminal, and PDs were measured. It was found that with the increase in the voltage level, the measured charge also increases, being greater than 1000 pC, which is the amplitude taken as a reference.…”
Section: Acceptance Limits Based On Pd Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Some studies use the maximum amplitude of 1000 pC as a reference to indicate PD activity in medium voltage machines, this threshold being based on international standards [42]. To verify this value, in [42], tests were realized in a hydro generator, where voltages of 7, 9, 10.5, and 11 kV were applied to the machine terminal, and PDs were measured. It was found that with the increase in the voltage level, the measured charge also increases, being greater than 1000 pC, which is the amplitude taken as a reference.…”
Section: Acceptance Limits Based On Pd Measurementsmentioning
confidence: 99%
“…and works in specific environments. Therefore, it would be most convenient to analyze the PD history of each asset, creating taylor-made decision rules [42,44,45,[63][64][65]. In addition, PDs are measured with different magnitudes, depending on the applied filter settings as well as the frequency response of sensors.…”
Section: State Of the Art In Measurement And Analysis Of Pdsmentioning
confidence: 99%
“…There are three main ways of heat transfer: introduction transfer, convection heat transfer and radiation heat transfer (Haţiegan et al, 2016). The insulation effect of green building materials is determined by the combined effects of these three heat transfer methods.…”
Section: Insulation Effect Characterization Of Green Building Materialsmentioning
confidence: 99%
“…Considering that, in the start-up phase of an energy group with a unitary power of 330 MW, the consumers of own services are fed from the National Energy System, according to the norms in force, it is necessary to monitor the supply voltage [1][2][3][4][5][6][7]. The electricity supply of the consumers of own services, afferent to an energy group with a unitary power of 330 MW, is made in the starting phase of the group, from the National Power System through a system of collector bars, known as "main bars" [8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…In the start-up phase of an energy group with a unitary power of 330 MW, the electricity supply of consumers of own services is realized through the main busbar system, so that after starting the group and entering it in parallel with the National Energy System, it will switch the power supply with electricity from a block own service transformer [5]. As it can be seen from Figure 1, the block proprietary service transformer is connected to the 330 MW synchronous generator terminals via a busbar system [8,9].…”
Section: Introductionmentioning
confidence: 99%