The Heavy Ion Beam Probing Development for WEGA Stellarator

Abstract: Abstract.The conceptual design for a Heavy Ion Beam diagnostic (HIBP) for the stellarator WEGA in Greifswald (Germany) is developed to provide the measurements of the radial profiles of the electric plasma potential, density and their fluctuations. Calculations of probing Na + beam trajectories were done for the various WEGA diagnostics ports with B 0 from 0.087T to 0.5T. They show that satisfactory access may be possible for C+-C-port combinations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2008
2008
2024
2024

Publication Types

Select...
4
1
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 5 publications
0
6
0
Order By: Relevance
“…The area of HIBP developments was expanded significantly after presentation our results at the international conferences. HIВP researches were performed in tokamaks: TM-4 (Moscow, 1978(Moscow, -1980, T-10 (Moscow, 1990-2018) [11][12][13], Tuman-3M (St. Petersburg, 1983 -now) [14], TJ-I (Madrid, 1991(Madrid, -1995 [15,16] and in stellarators: TJ-II (Madrid, 1996  now) [17], WEGA (Greifswald, 2004(Greifswald, -2009 [18][19][20][21] and Uragan-2M (Kharkiv, 1985  calculations, 2012  installation) [22]. Main parameters of devices and HIBPs are collected in Table 1.…”
Section: Implementation Of Hibp On Tokamaks and Stellaratorsmentioning
confidence: 99%
“…The area of HIBP developments was expanded significantly after presentation our results at the international conferences. HIВP researches were performed in tokamaks: TM-4 (Moscow, 1978(Moscow, -1980, T-10 (Moscow, 1990-2018) [11][12][13], Tuman-3M (St. Petersburg, 1983 -now) [14], TJ-I (Madrid, 1991(Madrid, -1995 [15,16] and in stellarators: TJ-II (Madrid, 1996  now) [17], WEGA (Greifswald, 2004(Greifswald, -2009 [18][19][20][21] and Uragan-2M (Kharkiv, 1985  calculations, 2012  installation) [22]. Main parameters of devices and HIBPs are collected in Table 1.…”
Section: Implementation Of Hibp On Tokamaks and Stellaratorsmentioning
confidence: 99%
“…When varying the beam's angle of injection by means of the primary beamline, the sample volume scans the plasma, which enables determining the potential profile evolution several (5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20) times during the discharge. The beam energy change enables the variation of the radial scan location at the plasma cross-section from shot to shot.…”
Section: Hibp Hardware and Probing Beam Featuresmentioning
confidence: 99%
“…The density in the ionization point can be obtained from the secondary beam current I t by the following relation: (1) where I b is the initial beam current, σ 12 is the effective ionization cross-section and λ the linear dimension of the SV along the trajectory.…”
Section: Hibp Hardware and Probing Beam Featuresmentioning
confidence: 99%
See 1 more Smart Citation
“…In collaboration with the Institute for Plasma Physics in Kharkov/Ukraine a Heavy Ion Beam Probe (HIBP) diagnostic is currently being tested on WEGA [7].…”
Section: Diagnostic Development Hibpmentioning
confidence: 99%