2013
DOI: 10.1088/1742-6596/425/18/182004
|View full text |Cite
|
Sign up to set email alerts
|

The ID21 Scanning X-ray Microscope at ESRF

Abstract: The ID21 Scanning X-ray Microscope (SXM) is optimized for micro-spectroscopy with submicron resolution in the 2 to 9.5 keV energy range. After a brief description of the microscope setup, we present here recent developments, in particular, the latest version of the compact Wavelength Dispersive Spectrometer and the refurbished cryo-stage.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
44
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 57 publications
(44 citation statements)
references
References 4 publications
0
44
0
Order By: Relevance
“…2.3.1 Micro-X-ray fluorescence and chemical maps in scanning mode lXRF data were collected at the X-ray micro-spectroscopy beamline ID21 at the European Synchrotron Radiation Facility (ESRF) [16]. Monochromatic radiation was extracted from an undulator coupled with a fixed-exit doublecrystal monochromator equipped with a Si(111) crystal and focused using a Kirkpatrick-Baez mirror pair to a typical beam size of 0.2 lm ver.…”
Section: Analytical Methods and Data Processingmentioning
confidence: 99%
“…2.3.1 Micro-X-ray fluorescence and chemical maps in scanning mode lXRF data were collected at the X-ray micro-spectroscopy beamline ID21 at the European Synchrotron Radiation Facility (ESRF) [16]. Monochromatic radiation was extracted from an undulator coupled with a fixed-exit doublecrystal monochromator equipped with a Si(111) crystal and focused using a Kirkpatrick-Baez mirror pair to a typical beam size of 0.2 lm ver.…”
Section: Analytical Methods and Data Processingmentioning
confidence: 99%
“…Apart from the sequential P extractions, we investigated the P fractionation in a sediment sample from 11.67 mcd (hole C) with unfocused X-ray absorption near-edge structure (XANES) spectroscopy. The analysis was conducted in April 2015 at the ID21 beamline at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France (see Salomé et al, 2013 for details on the beamline). Prior to analysis, the monochromator was calibrated against the first derivative of tricalcium phosphate (2149.43 eV).…”
Section: Bulk Phosphorus Analysis (Sedex and P Xanes)mentioning
confidence: 99%
“…The layouts of the beamlines are described in Borsboom et al (1998);Nikitenko et al (2008) and Salomé et al (2013), respectively. XAS measurements at the K-edges of Fe and Mn were performed at BM26a in the energy range 7.00-7.65 keV and 6.50-6.90 keV, respectively.…”
Section: Xas Of Blue Aggregates and Bulk Sedimentsmentioning