2014
DOI: 10.1063/1.4891139
|View full text |Cite
|
Sign up to set email alerts
|

The ISOLDE facility and the HIE-HISOLDE project: Recent highlights

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…Isobaric separation of singly-charged atomic or molecular ions is achieved with a magnetic mass separator, from where the ions are sent at a typical energy of 30-50 keV into several experimental beam lines. Experiments stationed at ISOLDE use the radioactive ion beams to do very precise mass measurements, ISOLTRAP (Mukherjee et al 2008, Wolf et al 2013, Lunney 2017, study decay properties, IDS (IDS Collaboration 2021), measure HFS and isotope shifts, CRIS (Cocolios et al 2013), and more (Butler 2005, Borge 2014, Borge et al 2015. ISOLDE features also two irradiation points located after the primary target at each target station in which standard ISOLDE targets as well as material samples can be irradiated.…”
Section: Isoldementioning
confidence: 99%
“…Isobaric separation of singly-charged atomic or molecular ions is achieved with a magnetic mass separator, from where the ions are sent at a typical energy of 30-50 keV into several experimental beam lines. Experiments stationed at ISOLDE use the radioactive ion beams to do very precise mass measurements, ISOLTRAP (Mukherjee et al 2008, Wolf et al 2013, Lunney 2017, study decay properties, IDS (IDS Collaboration 2021), measure HFS and isotope shifts, CRIS (Cocolios et al 2013), and more (Butler 2005, Borge 2014, Borge et al 2015. ISOLDE features also two irradiation points located after the primary target at each target station in which standard ISOLDE targets as well as material samples can be irradiated.…”
Section: Isoldementioning
confidence: 99%
“…Isobaric separation of singly-charged atomic or molecular ions is achieved with a magnetic mass separator, from where the ions are sent at a typical energy of 30 to 50 keV into several experimental beam lines. Experiments stationed at ISOLDE use the radioactive ion beams to do very precise mass measurements, ISOLTRAP (Wolf et al, 2013;Lunney, 2017;Mukherjee et al, 2008), study decay properties, IDS (IDS Collaboration, 2021), measure hyperfine structure and isotope shifts, CRIS (Cocolios et al, 2013), and more (Borge et al, 2015;Butler, 2005;Borge, 2014). ISOLDE features also two irradiation points located after the primary target at each target station in which standard ISOLDE targets as well as material samples can be irradiated.…”
Section: Isoldementioning
confidence: 99%