1992
DOI: 10.1016/0168-1176(92)80063-7
|View full text |Cite
|
Sign up to set email alerts
|

The Lamont—Doherty Geological Observatory Isolab 54 isotope ratio mass spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1994
1994
2015
2015

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 31 publications
(7 citation statements)
references
References 15 publications
0
7
0
Order By: Relevance
“…Internal precision of the individual analyses is a factor of two better than the external precision. Some of the Samoan samples were analyzed for Hf isotopes using the Lamont Isolab [England et al, 1992] using separation technique and measurement protocol described by Salters [1994]. The Ko'olau samples were treated similarly to the MORB powders and were analyzed on the NEPTUNE MC-ICP-MS. [14] Methods used at the Max-Planck-Institut were as follows.…”
Section: Samples and Methodsmentioning
confidence: 99%
“…Internal precision of the individual analyses is a factor of two better than the external precision. Some of the Samoan samples were analyzed for Hf isotopes using the Lamont Isolab [England et al, 1992] using separation technique and measurement protocol described by Salters [1994]. The Ko'olau samples were treated similarly to the MORB powders and were analyzed on the NEPTUNE MC-ICP-MS. [14] Methods used at the Max-Planck-Institut were as follows.…”
Section: Samples and Methodsmentioning
confidence: 99%
“…Ionisation of Th was drastically increased with ion sputtering to generate Th ions in a secondary ion mass spectrometer (SIMS), able to achieve figures > 2% for ionisation efficiency, although this was partly impaired by molecular and cluster interferences produced during sputtering, that required high mass resolution and/or energy filtering (England et al . ). Nevertheless, the SIMS approach enabled Th isotope amount ratios to be measured with an overall intermediate precision of 0.6% (2 RSD) on sample sizes ranging from 100 to 5 ng (England et al .…”
Section: Introductionmentioning
confidence: 97%
“…Hafnium isotopic measurements for 20 of 27 samples reported in Table 2 were carried out at NHMFL by HOT-SIMS techniques [Bizimis et al, 2003;Salters and Zindler, 1995] on the Lamont ISOLAB [England et al, 1992]. External reproducibility over a 2-year period was measured by repeat runs on JMC-475, with 176 Hf/ 177 Hf = 0.282200 ± 31 (2σ, n=44) [Bizimis et al, 2003].…”
Section: Measurement Techniquesmentioning
confidence: 99%