1991
DOI: 10.1016/0009-2614(91)80064-5
|View full text |Cite
|
Sign up to set email alerts
|

The magnetic circular dichroism and absorption spectra of C60 isolated in Ar matrices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

9
64
5

Year Published

1993
1993
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 133 publications
(78 citation statements)
references
References 11 publications
9
64
5
Order By: Relevance
“…At this level of CI approach, Marconi and Salvi [3] have concluded that: "for the lowest permitted states of Ti u symmetry the Α term is well reproduced in size and sign independently from the parametrization and the amount of configuration interaction used". We do not agree with that conclusion as the CNDO/S method used with the limited number of configurations yields the intensities and the magnetic moments of the Τ1u-symmetry states to be strongly at variance with the MCD experiment [4] and also with our later calculations [1]. Moreover, the energies and intensities calculated for the three low-energy T1 u states obtained by Marconi and Salvi [3,5] are also inconsistent with those recently found using the CNDO/S method employed at the same level of CI treatment [6].…”
Section: Introductioncontrasting
confidence: 72%
See 3 more Smart Citations
“…At this level of CI approach, Marconi and Salvi [3] have concluded that: "for the lowest permitted states of Ti u symmetry the Α term is well reproduced in size and sign independently from the parametrization and the amount of configuration interaction used". We do not agree with that conclusion as the CNDO/S method used with the limited number of configurations yields the intensities and the magnetic moments of the Τ1u-symmetry states to be strongly at variance with the MCD experiment [4] and also with our later calculations [1]. Moreover, the energies and intensities calculated for the three low-energy T1 u states obtained by Marconi and Salvi [3,5] are also inconsistent with those recently found using the CNDO/S method employed at the same level of CI treatment [6].…”
Section: Introductioncontrasting
confidence: 72%
“…In fact, such a trend is seen in Table. However, the CNDO/S method used with 171 configurations fits the experimental energies [4] at E (lT1u ) = 3.80 eV, Ε(2T1u) = 4.90 eV, Ε(3T1u ) = 5.96 eV, much better than CNDO/S method does with the larger number of 196 configurations. Specifically, the CNDO/S calculations with 196 configurations lead to energies which are significantly lower than those found in the experiment.…”
Section: Resultsmentioning
confidence: 91%
See 2 more Smart Citations
“…This can be extracted from the graph of the integrated strength f E defined in Eq. (29). The jumps at low energies give the f strengths of the discrete transitions.…”
Section: Application To C 60mentioning
confidence: 99%