2016
DOI: 10.1089/bfm.2015.0172
|View full text |Cite
|
Sign up to set email alerts
|

The Mechanics of Breast Pumping: Compression Stimuli Increased Milk Ejection

Abstract: Compression stimuli increased the efficacy of the breast pump, which is not only due to the effective formation milk ejection reflex but also directly to an additional squeezing of milk from the breast.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
6
0
2

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 13 publications
1
6
0
2
Order By: Relevance
“…In both apparatus the vacuum pressure was set at 152 mm Hg, but in the Laktopuls the ducts are additionally compressed, adding positive pressure to vacuum pressure. As a result, the difference between the intraductal pressure and the external environment increases and, as our research [6] proved, it results in an increase in the speed of milk expression.…”
Section: Laktopuls After the First 10 Minutes Of Milk Expression By Medelasupporting
confidence: 54%
“…In both apparatus the vacuum pressure was set at 152 mm Hg, but in the Laktopuls the ducts are additionally compressed, adding positive pressure to vacuum pressure. As a result, the difference between the intraductal pressure and the external environment increases and, as our research [6] proved, it results in an increase in the speed of milk expression.…”
Section: Laktopuls After the First 10 Minutes Of Milk Expression By Medelasupporting
confidence: 54%
“…If supplemental feeds are medically indicated, they should be accompanied by manual or mechanical milk expression, recognizing that direct breastfeeding usually provides more complete milk removal. 115 In a pilot RCT (N = 40), early limited formula supplementation for infants with $5% weight loss increased exclusive breastfeeding at 3 months post partum. 116 In a subsequent larger study (N = 164), early limited supplementation did not affect overall breastfeeding at 1 or 6 months but slightly increased rates of formula use at 1 month (36.7% vs 22.4%; P = .08), 105 decreased breastfeeding at 12 months (30% vs 48%; risk difference 218% [CI 234% to 23%]), and shortened the time to breastfeeding cessation (hazard ratio 0.65; 95% CI 0.43 to 0.97).…”
Section: Supplementationmentioning
confidence: 99%
“…ст., но в аппарате «Лактопульс» дополнительно протоки сжимаются, то есть к вакуумному давлению добавляется положительное давление. В результате разность давления между внутренним объемом протоков и пространством под накладкой увеличивается, что, как показали наши исследования [2], повышает скорость выведения молока.…”
Section: Discussionunclassified
“…В мире су-ществует большое количество вариантов таких аппаратов -молокоотсосов. Во втором типе [2], единственном к настоящему времени и получившем название «Лактопульс», так же как при выведении молока ребенком [3][4][5][6][7], на ареолу молочной железы одновременно воздействует и вакуум и сжатие. Надо отметить, что по морфофункциональным характеристикам молочные железы у женщин могут заметно отличаться, поэтому для успешного продолжения лактации следует выбирать аппарат в соответствии с особенностями молочных желез [1].…”
unclassified