1998
DOI: 10.1016/s0738-081x(98)00046-7
|View full text |Cite
|
Sign up to set email alerts
|

The nicotine transdermal system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(22 citation statements)
references
References 74 publications
0
22
0
Order By: Relevance
“…Regarding other nicotine patches the most common adverse effect is also the transient mild itching, erythema and burning at the application sites. 9,39) Mild itching and erythema were observed at the application sites after multiple doses of TNP as well. 23) In conclusion, the linear pharmacokinetics of nicotine in proportion to the surface area (Dose) was observed after single application of TNP in identical subjects.…”
Section: Discussionmentioning
confidence: 98%
See 1 more Smart Citation
“…Regarding other nicotine patches the most common adverse effect is also the transient mild itching, erythema and burning at the application sites. 9,39) Mild itching and erythema were observed at the application sites after multiple doses of TNP as well. 23) In conclusion, the linear pharmacokinetics of nicotine in proportion to the surface area (Dose) was observed after single application of TNP in identical subjects.…”
Section: Discussionmentioning
confidence: 98%
“…The transdermal nicotine patch (TNP), containing approximately 16.6 and 24.9 mg of nicotine per 20 and 30 cm 2 thin multilayer film laminate patch , is designed to deliver about 10 and 15 mg of nicotine in 16 h of application (31 mg/cm 2 /h). 9) We investigated the linearity of nicotine pharmacokinetics and safety after single application of different strengths of TNP (1 sheet of TNP-20, 2 sheets of TNP-20, and 1 sheet of TNP-30) and directly compared the plasma nicotine concentrations after application of 1 sheet of TNP-30 with those during controlled cigarette smoking.…”
mentioning
confidence: 99%
“…As reviewed by Gore and Chien (1998), the pharmacokinetic C max (±SD) values for the 5 mg and 10 mg patches are 3.5 ng/mL (0.7) and 6.9 ng/mL (2.0) respectively, and the T max (±SD) value for both patches is 9 hr (4).…”
Section: Apparatusmentioning
confidence: 98%
“…Matrix systems may have only three layers without a semi-permeable membrane or just two layers by incorporating the drug directly into a polymeric adhesive matrix. Matrix release profiles are expressed as Higuchi's model, which is characterized by passive diffusion from the polymeric matrix (Gore, Chien, 1998).…”
Section: Kinetic Studiesmentioning
confidence: 99%
“…Drug plasmatic levels can be safely assured using these commercial devices for approximately 16 to 24 hours to provide relief of symptoms related to nicotine abstinence (Gore, Chien, 1998).…”
Section: Introductionmentioning
confidence: 99%