2002
DOI: 10.1007/s003390201755
|View full text |Cite
|
Sign up to set email alerts
|

The novel reflectometer REFSANS for analyses of liquid and soft surfaces at the new research reactor FRM-II in Munich, Germany

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 0 publications
0
6
0
Order By: Relevance
“…The measurements were performed at the REFSANS neutron reflectometer at FRM II in Munich. REFSANS is a time-of-flight (ToF) instrument for reflectometry at the solid–liquid interface. , We make use of isotope labeling (i.e., deuteration of the lipid chains) and contrast variation by exchanging D 2 O against a mixture of H 2 O/D 2 O. This allows us to determine the volume fraction of the lipids ( x 1 ) and the hydration water fraction ( x 2 ) as a function of depth as well as the scattering length density (SLD) profile of the bilayer.…”
Section: Methodsmentioning
confidence: 99%
“…The measurements were performed at the REFSANS neutron reflectometer at FRM II in Munich. REFSANS is a time-of-flight (ToF) instrument for reflectometry at the solid–liquid interface. , We make use of isotope labeling (i.e., deuteration of the lipid chains) and contrast variation by exchanging D 2 O against a mixture of H 2 O/D 2 O. This allows us to determine the volume fraction of the lipids ( x 1 ) and the hydration water fraction ( x 2 ) as a function of depth as well as the scattering length density (SLD) profile of the bilayer.…”
Section: Methodsmentioning
confidence: 99%
“…The wavelength resolution of the incident beam is controlled using a double high-speed chopper system. The separation distance between the choppers was about 2.31 m and the system was operated as described by Kampmann et al (2002Kampmann et al ( , 2003Kampmann et al ( , 2004Kampmann et al ( , 2006. The slits on both choppers can be varied between 0 and 120 .…”
Section: Time-of-flight Gisansmentioning
confidence: 99%
“…GISANS experiments were performed in TOF mode at the horizontal reflectometer REFSANS (Kampmann et al, 2002(Kampmann et al, , 2003 at the Munich research reactor Heinz Maier-Leibnitz (MLZ). The TOF-GISANS measurements used an incident angle of 0.50 , a sample-detector distance of 10.7 m and a neutron wavelength band of 0.25-1.49 nm selected by a chopper using a resolution Á/ = 10%.…”
Section: Grazing-incidence Small-angle Neutron Scatteringmentioning
confidence: 99%