2001
DOI: 10.1109/94.933375
|View full text |Cite
|
Sign up to set email alerts
|

The orientational order in nematic liquid crystals from birefringence measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
41
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(42 citation statements)
references
References 8 publications
1
41
0
Order By: Relevance
“…Measure− ment of optical anisotropy, i.e., Dn provides not only the most simplest and convenient, but also yields direct and very precise results [13,21]. Thus, the optical methods are most frequently used for the calculation of order parameter of LCs [14,24]. Quite a few molecular structures with high Dn values have been investigated by using different methods [2][3][4]25].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Measure− ment of optical anisotropy, i.e., Dn provides not only the most simplest and convenient, but also yields direct and very precise results [13,21]. Thus, the optical methods are most frequently used for the calculation of order parameter of LCs [14,24]. Quite a few molecular structures with high Dn values have been investigated by using different methods [2][3][4]25].…”
Section: Introductionmentioning
confidence: 99%
“…However, assuming the validity of a local field model, the microscopic order pa− rameter can be determined from the knowledge of macro− scopic bulk tensorial properties [17,18]. Several methods have been developed for the measurement of macroscopic order parameter (Q) in a LC [13,14,16,[18][19][20][21]. Measure− ment of optical anisotropy, i.e., Dn provides not only the most simplest and convenient, but also yields direct and very precise results [13,21].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As the temperature increases, the extraordinary refractive index decreases sharply while the ordinary refractive index decreases initially but gradually increases near the clearing temperature. Behavior of n e and n o for MLC-9200-000 and MLC-6608 is found to be similar as in the case of other organic liquids [12,15,16]. Figure 2 depicts the temperature dependence of experimental results and theoretical curves of birefringence ∆n.…”
Section: Resultsmentioning
confidence: 92%
“…Two procedures are discussed for the determination of order parameter. The first one is a simple procedure solely based on birefringence measurements [12]. This procedure consists in the following steps: measurements of birefringence ∆n, determination of ∆n o using extrapolation, and calculation of order parameter.…”
Section: Introductionmentioning
confidence: 99%