2020
DOI: 10.37934/arfmts.76.1.113123
|View full text |Cite
|
Sign up to set email alerts
|

The Performance Simulation of The New R463A HFC/HFO/Carbon Dioxide Refrigerant with Lower GWP, As an Alternate Option for The R404A Refrigeration System

Abstract: This study presents the performance simulation of the R463A that has been developed to be retrofitted to replace the R404A. The R463A is primarily composed of hydrofluorocarbons/hydrocarbon/carbon dioxide (HFCs/HCs/CO2). The R463A refrigerant (GWP=1494) is a non azeotropic mixture of R32 (36%), R125 (30%), R134a (14%), R1234yf (14%), and R744 (6%). It is composed of polyol ester oil (POE), and classified as a Class A1 incombustible and non-toxic refrigerant. The R463A has a higher cooling capacity (Qe) than th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 35 publications
(49 reference statements)
0
5
0
Order By: Relevance
“…13 below, which shows the refrigerant mixtures with R1270 fixed at 1% and various mass percentages of R134, R32, and R125. The refrigerant proportion mixed with R125 was, more or less, similar to that of the R32 mixture, and also possessed the Class A1 non-flammability property, similar to R410A (which is comprised of 50% R125 and 50% R32) [81][82][83]. The class A2 mixed refrigerants had a mass percentage of R32 higher than that of R125, similar to R452B (R32/125/1234yf [67/7/26]).…”
Section: Resultsmentioning
confidence: 99%
“…13 below, which shows the refrigerant mixtures with R1270 fixed at 1% and various mass percentages of R134, R32, and R125. The refrigerant proportion mixed with R125 was, more or less, similar to that of the R32 mixture, and also possessed the Class A1 non-flammability property, similar to R410A (which is comprised of 50% R125 and 50% R32) [81][82][83]. The class A2 mixed refrigerants had a mass percentage of R32 higher than that of R125, similar to R452B (R32/125/1234yf [67/7/26]).…”
Section: Resultsmentioning
confidence: 99%
“…The results illustrated the relationships of all parameters, such as GWP, boiling point, refrigerant effect, heat rejection, refrigerant work, evaporator pressure, high pressure, and cooling coefficient of performance (COPc), as well as the result of the decision tree function through datamining using the RapidMiner software (which came first in the 2013 KDnuggets annual software poll [80][81][82]), as shown in Figure 9 below. The baseline refrigerant, using R134a, R32, R125, and R1270, was determined from the literature review [83][84][85][86][87][88][89].…”
Section: Methodsmentioning
confidence: 99%
“…Workflow of the digital semi-hermetic compressor is illustrated in Figure 7 and Figure 8, and the fixed-speed compressor rack compressor and digital scroll are illustrated in Figure 9, Figure 10, and Figure 11. A power meter data logger and temperature data logger were used to measured power consumption (W), voltage (V), current (I), power factor (PF), frequency (Hz), evaporator temperature (TEV), condenser temperature (TCD), liquid temperature (TLQ), sub cool temperature (TSC), gas temperature (TG), and superheat temperature (TSH) [25][26][27].…”
Section: Digital Semi-hermetic Compressormentioning
confidence: 99%