2007
DOI: 10.1016/j.cmpb.2007.01.003
|View full text |Cite
|
Sign up to set email alerts
|

The physiology analysis system: An integrated approach for warehousing, management and analysis of time-series physiology data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2008
2008
2015
2015

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 7 publications
0
7
0
Order By: Relevance
“…The vital signs were measured by Propaq 206EL transport monitors (Protocol Systems, Beaverton, OR), downloaded to an attached personal digital assistant, and ultimately stored in our database. 13 The variables consisted of electrocardiogram (ECG), photoplethysmogram, and respiratory waveform signals recorded at 182, 91, and 23 Hz, respectively, and their corresponding monitor-calculated vital signs, recorded at 1-second intervals (HR, oxygen saturation of arterial hemoglobin [SaO 2 ], and respiratory rate [RR]). In addition, SBP, mean arterial pressure (MAP), and diastolic blood pressure (DBP) were collected intermittently at multiminute intervals.…”
Section: Methodsmentioning
confidence: 99%
“…The vital signs were measured by Propaq 206EL transport monitors (Protocol Systems, Beaverton, OR), downloaded to an attached personal digital assistant, and ultimately stored in our database. 13 The variables consisted of electrocardiogram (ECG), photoplethysmogram, and respiratory waveform signals recorded at 182, 91, and 23 Hz, respectively, and their corresponding monitor-calculated vital signs, recorded at 1-second intervals (HR, oxygen saturation of arterial hemoglobin [SaO 2 ], and respiratory rate [RR]). In addition, SBP, mean arterial pressure (MAP), and diastolic blood pressure (DBP) were collected intermittently at multiminute intervals.…”
Section: Methodsmentioning
confidence: 99%
“…The complete investigational data set was subsequently uploaded to our data warehousing system. 23 Protected health information was not included. All subsequent data analyses were performed using MATLAB (version 7; MathWorks, Natick, MA).…”
Section: Clinical Data Collectionmentioning
confidence: 99%
“…25 The original data were imported from the Trauma Vitals Database, which contains clinical data and continuous physiologic data from trauma patients transported from the scene of injury by helicopter service to the Level I unit at the Memorial Hermann Hospital in Houston, TX. Additional details about the trauma population and the Emergency Medical Service are available in.…”
Section: Settingmentioning
confidence: 99%
“…RTS was automatically-computed from (a) the mean of all reliable RR and SBP data in the initial 15 minutes of a subject's Propaq electronic record; versus (b) the mean of less reliable RR and SBP data in the initial 15 minutes. Data were extracted using the ad hoc filtering capabilities of the Physiology Analysis System, 25 and the computations were performed using routines we developed in the MatLab v7.1 computing environment (MathWorks; Natick, MA).…”
Section: Reliable Versus Unreliable Datamentioning
confidence: 99%