2008
DOI: 10.1016/j.meddos.2007.05.001
|View full text |Cite
|
Sign up to set email alerts
|

The Potential for Dose Dumping in Normal Tissues with IMRT for Pelvic and H&N Cancers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2009
2009
2015
2015

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 27 publications
0
13
0
Order By: Relevance
“…Rectum was contoured in full, from rectosigmoid flexure to anorectal junction. 8,9 In the text, volumes on planning CT means the volumes on the treatment planning CT day, and treatment fraction means the treatment day. The Varian Eclipse treatment planning system ͑Varian Medical Systems, Palo Alto, CA͒ was used to generate 5-field IMRT plans with five gantry angles ͑250°, 315°, 45°, 110°, and 180°͒.…”
Section: Methodsmentioning
confidence: 99%
“…Rectum was contoured in full, from rectosigmoid flexure to anorectal junction. 8,9 In the text, volumes on planning CT means the volumes on the treatment planning CT day, and treatment fraction means the treatment day. The Varian Eclipse treatment planning system ͑Varian Medical Systems, Palo Alto, CA͒ was used to generate 5-field IMRT plans with five gantry angles ͑250°, 315°, 45°, 110°, and 180°͒.…”
Section: Methodsmentioning
confidence: 99%
“…''Dose dumping'' behind the spinal cord is a known potential problem in head and neck IMRT [18], as the optimisation attempts to boost dose to PTVs while sparing the spinal cord itself. This can lead to a doughnut-style ring of high dose around the spared spinal cord and is particularly undesirable because of the risk that weight loss or set-up errors could cause the cord position to relax into the high-dose area.…”
Section: Treatment Planningmentioning
confidence: 99%
“…2,6,7 This tight dose gradient allows an escalated tumoricidal dose to be delivered to the prostate while abutting or in close proximity to GI and GU structures. 3,9,10 IMRT has proven to lower rates of complications associated with normal tissue structures. 4,8,[11][12][13] Unlike 3-dimensional conformal radiotherapy, IMRT planning requires dose and volume objectives to be assigned to target tissues as well as critical structures.…”
Section: Introductionmentioning
confidence: 99%
“…7 This phenomenon has been coined "dose dumping" by some authors. 7,9 Dose dumping often occurs in nontarget tissues and can result in increased dose to normal tissues. 9 To reduce unwanted dose deposition in normal tissues, a series of tuning structures should be created.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation