2018
DOI: 10.1097/ana.0000000000000454
|View full text |Cite
|
Sign up to set email alerts
|

The Shikani Optical Stylet as an Alternative to Awake Fiberoptic Intubation in Patients at Risk of Secondary Cervical Spine Injury: A Randomized Controlled Trial

Abstract: This study validates the efficacy of both SOS and flexible fiberoptic bronchoscope for awake oral intubation in patients with cervical spine instability. SOS has been found to be more effective in reducing time to intubation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
32
0
4

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(36 citation statements)
references
References 13 publications
0
32
0
4
Order By: Relevance
“…Furthermore, the high-resolution eyepiece with light source can be used independently, or connected with a camera or a monitor. It has been widely used in clinic because of its fast, effective and little effect on hemodynamics [2,3].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, the high-resolution eyepiece with light source can be used independently, or connected with a camera or a monitor. It has been widely used in clinic because of its fast, effective and little effect on hemodynamics [2,3].…”
Section: Discussionmentioning
confidence: 99%
“…The Shikani optical stylet (SOS) (Clarus Medical, Minneapolis, MN) is one of the most commonly used fiberoptic stylets for intubation. It not only has the characteristics of a fiberoptic bronchoscope but also very light and convenient [2,3]. UGTI and SOS-aided tracheal intubation have some similar manipulations in the intubation: opening the mouth with hands, placing the styletted tube, and inserting the tube with the guidance of ultrasound or light spot and optical stylet.…”
Section: Introductionmentioning
confidence: 99%
“…It has been widely used in clinic because of its fast, effective and little effect on hemodynamics. 2,3 Ultrasound technology is more and more used in clinical anesthesia due to its safe, reliable, repeatable and easy to realize characteristics. In the case of endotracheal intubation, using ultrasound image, we can determine the endotracheal tube size, [5][6][7] observe the position of cricothyroid membrane and glottis, 1,4,5,8 guide tracheal intubation, 1,4,5 judge whether the tracheal tube enters the trachea, 1,4,5,9 and judge whether the position of tracheal tube is correct.…”
Section: Discussionmentioning
confidence: 99%
“…It not only has the characteristics of a beroptic bronchoscope but also very light and convenient. 2,3 UGTI and SOS-aided tracheal intubation have some similar manipulations in the intubation: opening the mouth with hands, placing the styletted tube, and inserting the tube with the guidance of ultrasound or light spot and optical stylet. And they are particularly effective for some special patients, who has limitation of mouth opening or di cult visualization of the airway obscured by secretions or blood.…”
Section: Introductionmentioning
confidence: 99%
“…It not only has the characteristics of a beroptic bronchoscope but also very light and convenient. 2,3 Ultrasound and SOS have some similar manipulations in the intubation: opening the mouth with hands, placing the styletted tube, and inserting the tube with the guidance of ultrasound or light spot and optical stylet. The SOS are usually particularly effective for some special patients, who has limitation of mouth opening or di cult visualization of the airway obscured by secretions or blood.…”
Section: Introductionmentioning
confidence: 99%