2001
DOI: 10.1143/jjap.40.580
|View full text |Cite
|
Sign up to set email alerts
|

The Study on Ferromagnetic Resonance Linewidth for NM/80NiFe/NM (NM=Cu, Ta, Pd and Pt) Films

Abstract: The out-of-plane angular dependence of ferromagnetic resonance (FMR) was measured for NM/80NiFe(Py)/NM (NM=Cu, Ta, Pd and Pt) films with various Py, Cu and Ta thicknesses fabricated by magnetron sputtering. The out-of-plane angular dependences of FMR resonance field and linewidth were analyzed using Landau-Lifshitz-Gilbert equation taking account of broadening of linewidth due to magnetic inhomogeneities in a film. Magnetic inhomogeneities were assumed to be the fluctuation of magnitude and direction of the e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

15
223
2

Year Published

2002
2002
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 337 publications
(240 citation statements)
references
References 21 publications
15
223
2
Order By: Relevance
“…Enhancement of the damping constant a 0 a 2 a 0 can be expressed in terms of the scattering matrix at the Fermi energy of a ferromagnetic film in contact with normal metal reservoirs, which can be readily obtained by model or first-principles calculations. Our numerical estimates of a 0 compare well with recent experimental results [12]. Earlier experiments reported in Ref.…”
supporting
confidence: 90%
See 3 more Smart Citations
“…Enhancement of the damping constant a 0 a 2 a 0 can be expressed in terms of the scattering matrix at the Fermi energy of a ferromagnetic film in contact with normal metal reservoirs, which can be readily obtained by model or first-principles calculations. Our numerical estimates of a 0 compare well with recent experimental results [12]. Earlier experiments reported in Ref.…”
supporting
confidence: 90%
“…The damping is significant for transition metal films thinner than about 10 nm. Recent experiments on permalloy films [12] are well explained.…”
mentioning
confidence: 76%
See 2 more Smart Citations
“…In the biaxial NiO, the voltages are much weaker, and there is no spin-flop enhancement of the dc component. Spin pumping is a versatile tool for probing spin dynamics in ferromagnets [1][2][3][4][5][6]. The magnitude of the pumped spin currents reveals information about the magnetization dynamics and the electron-magnon coupling at interfaces [7][8][9].…”
mentioning
confidence: 99%