2012
DOI: 10.1038/pj.2011.143
|View full text |Cite
|
Sign up to set email alerts
|

The systematic study of the microstructure of crosslinked copolymers from siloxane macromonomers and methacrylates by changes in composition and components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 18 publications
0
5
0
Order By: Relevance
“…GPC using RI detection generated chromatograms that showed a degree of bimodal character and higher than expected polydispersities. However, this is typical of diblock polymers that possess polymer blocks with very different refractive indices . For example, Armes et al also reported bimodal peaks when studying the GPC properties of a series of fluoro-containing diblock polymers .…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…GPC using RI detection generated chromatograms that showed a degree of bimodal character and higher than expected polydispersities. However, this is typical of diblock polymers that possess polymer blocks with very different refractive indices . For example, Armes et al also reported bimodal peaks when studying the GPC properties of a series of fluoro-containing diblock polymers .…”
Section: Resultsmentioning
confidence: 99%
“…However, this is typical of diblock polymers that possess polymer blocks with very different refractive indices. 16 For example, Armes et al also reported bimodal peaks when studying the GPC properties of a series of fluoro-containing diblock polymers. 17 In our case the refractive index of the PTFEMA block is 1.41, and this is much lower than the refractive index of poly(ethylene glycol), which is 1.47.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Silicone-acrylic block, segmented and graft copolymers and interpenetrating networks have also been extensively investigated . In addition to basic studies on the composition dependent structure-morphology-surface behavior (270,274,276,281,282,284,285,290), these materials were also investigated as protective coatings (271,279,287), adhesives (273,277,283), membranes (286,288,289)and biomaterials (268,272).…”
Section: Figure 19mentioning
confidence: 99%
“…TFEMA is utilized in various commercial applications because of its relatively low refractive index. [48][49][50][51] As we shall see, this particular monomer/solvent combination offers a unique opportunity to perform comparative experiments that shed new light on how RAFT dispersion polymerizations differ from conventional RAFT solution polymerizations.…”
Section: Introductionmentioning
confidence: 99%