1981
DOI: 10.1029/jb086ib09p07843
|View full text |Cite
|
Sign up to set email alerts
|

The use of height data in gravity field approximation by collocation

Abstract: The accuracy of a gravity field model depends on the amount of available data and on the variation of the gravity field. When topographic height data are available, for example, in the form of a digital terrain model, it is possible to smooth the gravity field on a local scale by removing the gravitational effects calculated from models of the topographic masses. In this way, significant improvements of the prediction results are obtained in mountainous areas. In this paper we describe methods for the calculat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
160
0
9

Year Published

1983
1983
2015
2015

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 223 publications
(170 citation statements)
references
References 4 publications
1
160
0
9
Order By: Relevance
“…Thus isostatic reduction, pragmatically regarded as trend removal, is essential for the practical application of least-squares collocation in mountainous regions (Forsberg and Tscherning, 1981).…”
Section: Application Of Collocation To Geoid Determinationmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus isostatic reduction, pragmatically regarded as trend removal, is essential for the practical application of least-squares collocation in mountainous regions (Forsberg and Tscherning, 1981).…”
Section: Application Of Collocation To Geoid Determinationmentioning
confidence: 99%
“…1) Relevant formulas can be found in (Forsberg and Tscherning, 1981) with references to (MacMillan, 1958, pp. 78-79) and (Jung, 1961, p. 167).…”
mentioning
confidence: 99%
“…180 181 182 C is the classical terrain correction, computed by rectangular prism 183 integration method, taking into account the resolution of the digital 184 elevation model (Forsberg and Tscherning, 1981), B is the Bouguer 185 correction:…”
mentioning
confidence: 99%
“…El geoide del centro Peninsular fue refinado teniendo en cuenta los efectos terreno gracias a un mejor modelo digital del terreno proporcionado por la Defense Mapping Agency Aerospace Center, utilizando la técnica del modelo residual del terreno (Forsberg et al 1981), (Gil 1993), , (Sevilla 1995 La primera determinación de un geoide gravimétrico en la Península Ibérica y regiones colindantes se obtuvo en 1994 utilizando la técnica clásica de resolución de la integral de Stokes (Sevilla 1994).…”
Section: Modelos Regionales Sobre La Penínsulaunclassified
“…Si lo que pretendemos es predecir la cantidad con un modelo continental o regional, basado en la técnica eliminar-restaurar (Forsberg et al 1981), (Albertella et al 1994), , se procederá de la siguiente manera: 1) Definiremos una malla lo suficientemente amplia en la que también aplicaremos la técnica eliminar-restaurar. Esta malla tendrá un espaciado en latitud y longitud correspondiente con la resolución del modelo de geoide utilizado, en este caso particular se ha utilizado tanto para el modelo EGG97 como para el IBERGEO95 un mallado de 1.5 X 1.5 minutos sobre un área que va desde los 35º45' N a los 43º45' N en latitud y -9º30' W a 4º30' E en longitud (área sobre la que está determinado el modelo IBERGEO95), de esta forma aseguramos que el error cometido por el hecho de no considerar el total de la malla (error que se producirá únicamente en el caso del modelo EGG97) sea mínimo, y, por supuesto, mucho menor de 0.03 mgal.…”
Section: Análisis Y Ajuste De Los Diferentes Modelos De Geoideunclassified