2008
DOI: 10.1118/1.2968093
|View full text |Cite
|
Sign up to set email alerts
|

The x‐ray light valve: A low‐cost, digital radiographic imaging system—Spatial resolution

Abstract: An x-ray light valve ͑XLV͒ coupled with an optical scanner has the potential to meet the need for a low-cost, high quality digital imaging system for general radiography. The XLV/scanner concept combines three well-established, and hence, low-cost technologies: An amorphous selenium ͑a-Se͒ layer as an x-ray-to-charge transducer, a liquid crystal ͑LC͒ cell as an analog display, and an optical scanner for image digitization. The XLV consists of an a-Se layer and LC cell in a sandwich structure which produces an … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…The spatial resolution of the presented system depends primarily on the pixel size of the system, which corresponds to the scan pitch, and on the spot size, that is, the effective size of the primary beam delivered to the sample surface in each step. The spot size can be controlled during the experiments by using different collimators.…”
Section: Characterizationmentioning
confidence: 99%
“…The spatial resolution of the presented system depends primarily on the pixel size of the system, which corresponds to the scan pitch, and on the spot size, that is, the effective size of the primary beam delivered to the sample surface in each step. The spot size can be controlled during the experiments by using different collimators.…”
Section: Characterizationmentioning
confidence: 99%
“…This could potentially eliminate the necessity for a preliminary incisional biopsy before proceeding with the chosen treatment such. 3 Accurate diagnosis of different types of cysts and intraosseous tumors in the maxillofacial region is a challenging task, it is mainly due to their similar and common presentations in conventional panoramic dental x-rays. 4 Additionally, it is rare to find incidentally this type of lesions, they are almost always discovered when the patient consults for a feeling of dissatisfaction or increase in volume in the area.…”
Section: Introductionmentioning
confidence: 99%
“…The key consideration is whether these methods can reliably and accurately offer swift diagnoses based solely on the images. This could potentially eliminate the necessity for a preliminary incisional biopsy before proceeding with the chosen treatment such 3 …”
Section: Introductionmentioning
confidence: 99%