2018
DOI: 10.1007/s10973-018-7956-6
|View full text |Cite
|
Sign up to set email alerts
|

Thermal analysis used to guide the production of thymol and Lippia origanoides essential oil inclusion complexes with cyclodextrin

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
18
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 36 publications
(22 citation statements)
references
References 25 publications
4
18
0
Order By: Relevance
“…The diffractograms of the RV products showed no drug’s crystal signals, demonstrating the amorphous state of products probably due to their protection of PX in the cavity of CDs cyclodextrins. The results obtained in the current study are in agreement with previous studies reporting on the complexation of Hp-β-CD [14], Me-β-CD, and β-CD with PX [24].…”
Section: Resultssupporting
confidence: 93%
See 2 more Smart Citations
“…The diffractograms of the RV products showed no drug’s crystal signals, demonstrating the amorphous state of products probably due to their protection of PX in the cavity of CDs cyclodextrins. The results obtained in the current study are in agreement with previous studies reporting on the complexation of Hp-β-CD [14], Me-β-CD, and β-CD with PX [24].…”
Section: Resultssupporting
confidence: 93%
“…Physical mixtures shows the presence of both components (PX and CD). The FI-IR spectra of native Hp-β-CD, Me-β-CD, and β-CD are in broad agreement with previous reported data [14,24], whereas characteristic peaks attributed to the presence of PXM are clearly visible in the dominant physical mixtures. In the case of the inclusion complexes, broadened peaks are the dominating features in the spectra in accordance with previous studies [14,24].…”
Section: Resultssupporting
confidence: 91%
See 1 more Smart Citation
“…The spectra were recorded between 4000 and 600 cm −1 at an optical resolution of 4 cm −1 using an attenuated total reflection device. The correlation coefficient between fresh and aged samples [28] was calculated using the FTIR Essential software (Operant LLC, Madison, WIS, USA).…”
Section: Fourier Transform Infrared Spectroscopy (Ftir)mentioning
confidence: 99%
“…Moreover, the drug content of all formulations fulfills the pharmacopoeial range of 90-110% [40]. Moreover, a high correlation index was observed among the spectra of the fresh and aged samples for all extrudates (r > 0.9, Table 2), providing evidence that the chemical integrity of these systems would also be maintained during the shelf period [28]. Regarding the morphological aspects, the extrudate granules showed a regular size and a rounded shape (Figure 2).…”
Section: Extrusion Conditions and Sample Agingmentioning
confidence: 99%