2015
DOI: 10.1016/j.ijrefrig.2015.04.010
|View full text |Cite
|
Sign up to set email alerts
|

Thermodynamic analyses on an ejector enhanced CO2 transcritical heat pump cycle with vapor-injection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
30
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 70 publications
(31 citation statements)
references
References 48 publications
1
30
0
Order By: Relevance
“…On the other hand, methanol is toxic and highly flammable; therefore, important preventive measures should be taken. Recently, many studies have focused on the carbon dioxide (R744) refrigerant: CO 2 is a natural substance, is nonflammable and has negligible GWP and zero ODP [205,[210][211][212][213][214][215][216][217][218][219][220][221][222][223][224][225][226][227]. In particular, the refrigeration cycles using carbon dioxide are transcritical (the critical temperature of CO 2 is approximately 30.85°C).…”
Section: Working Fluids In Ejector Refrigerationmentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, methanol is toxic and highly flammable; therefore, important preventive measures should be taken. Recently, many studies have focused on the carbon dioxide (R744) refrigerant: CO 2 is a natural substance, is nonflammable and has negligible GWP and zero ODP [205,[210][211][212][213][214][215][216][217][218][219][220][221][222][223][224][225][226][227]. In particular, the refrigeration cycles using carbon dioxide are transcritical (the critical temperature of CO 2 is approximately 30.85°C).…”
Section: Working Fluids In Ejector Refrigerationmentioning
confidence: 99%
“…In addition, a comprehensive exergy analysis was implemented, and the resulting second law efficiencies obtained were 6.6% and 7.52% for conventional and ejector based systems, respectively. Bai et al [222] studied a CO 2 TERS cycle with a sub-cooler (ESCVI). The proposed cycle was found to have better performance than the conventional vapor injection cycle, with an increase of COP up to 7.7%.…”
Section: One Ejector Co 2 Tersmentioning
confidence: 99%
“…The thermodynamic analysis is described by means of the mass, momentum and energy balance equations. Mass balance equation [2,[43][44][45]:…”
Section: Calculation Unit Algorithm Structurementioning
confidence: 99%
“…Geometrical data of the existing SEPS is indicated in Table 1 [46]. Momentum balance equation [2,43,44]:…”
Section: Calculation Unit Algorithm Structurementioning
confidence: 99%
See 1 more Smart Citation