2014
DOI: 10.1088/1748-0221/9/05/p05005
|View full text |Cite
|
Sign up to set email alerts
|

Thick-lens velocity-map imaging spectrometer with high resolution for high-energy charged particles

Abstract: A novel design for a velocity-map imaging (VMI) spectrometer with high resolution over a wide energy range surpassing a standard VMI design is reported. The main difference to a standard three-electrode VMI is the spatial extension of the applied field using 11 electrodes forming a thick-lens. This permits measurements of charged particles with higher energies while achieving excellent resolving power over a wide range of energies. Using SIMION simulations, the thick-lens VMI is compared to a standard design f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
42
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 60 publications
(43 citation statements)
references
References 36 publications
1
42
0
Order By: Relevance
“…Our VMI spectrometer follows well-documented design and operation, e.g., 79 , 95 . An effusive gas jet of the target hydrocarbon molecules intersects the laser beam inside the spectrometer, which is composed of an electrostatic lens system that focuses photofragments to specific radii on the detector depending upon their transverse momenta.…”
Section: Methodsmentioning
confidence: 99%
“…Our VMI spectrometer follows well-documented design and operation, e.g., 79 , 95 . An effusive gas jet of the target hydrocarbon molecules intersects the laser beam inside the spectrometer, which is composed of an electrostatic lens system that focuses photofragments to specific radii on the detector depending upon their transverse momenta.…”
Section: Methodsmentioning
confidence: 99%
“…Pulse shapes are monitored with a Second-Harmonic-Generation FrequencyResolved Optical Gating (SHG FROG) 28 scheme. The thick-lens VMI spectrometer used in these experiments has been described in other publications [29][30][31] and contains an effusive jet to deliver the target gas, similar to the one described by Ghafur and co-workers. 32 As shown in Fig.…”
Section: Experimental Apparatusmentioning
confidence: 99%
“…The 11 electrode assembly was mounted in "thick lens" configuration. 9 in order to maintain a good energy resolution over a broad kinetic energy range (⇠ 0 -100 eV in our case). The VMI was designed using a trajectory simulation of charged particles with the SIMION software.…”
Section: The Velocity Map Imaging Spectrometermentioning
confidence: 99%