2005
DOI: 10.1016/j.bios.2004.09.021
|View full text |Cite
|
Sign up to set email alerts
|

Thin-film IrO pH microelectrode for microfluidic-based microsystems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
102
1
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 118 publications
(112 citation statements)
references
References 41 publications
8
102
1
1
Order By: Relevance
“…In the considered range, the potential changes linearly with increasing pH, with a sensitivity of -74±3 mV/pH for the forward scan, and -75±5 mV/pH for the backward scan. Our sensor with the IrOx film showed a near super-Nernstian response with sensitivity values similar to the ones reported in [19].…”
Section: Ph Sensorsupporting
confidence: 85%
See 2 more Smart Citations
“…In the considered range, the potential changes linearly with increasing pH, with a sensitivity of -74±3 mV/pH for the forward scan, and -75±5 mV/pH for the backward scan. Our sensor with the IrOx film showed a near super-Nernstian response with sensitivity values similar to the ones reported in [19].…”
Section: Ph Sensorsupporting
confidence: 85%
“…The drugs ETO, MTX and ETD purchased as a powder (Sigma-Aldrich) were dissolved in Dimethyl sulfoxide due to their low solubility in water. For the pH sensor, a solution of Iridium(IV) chloride hydrate (99.9% metals basis, from Sigma Aldrich), H 2 O 2 (30%), oxalic acid dihydrate (98%, from Sigma Aldrich), and potassium carbonate anhydrous (99%, from Alfa Aesar) was prepared for the deposition of the Iridium Oxide film (IrOx), as described in [19]. …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A detailed protocol to deposit the iridium oxide films onto the Pt-films and their properties was described in previous work (Ges et al, 2005(Ges et al, , 2007. The deposition solution was prepared based on the method proposed by Yamanaka (1989Yamanaka ( , 1991 and Marzouk et al (1998;Marzouk, 2003).…”
Section: Iro X Ph Sensitivity and Reference Electrodesmentioning
confidence: 99%
“…However, traditional glass electrodes have many disadvantages, such as high cost, mechanical fragility, difficult to miniaturize, need for wet storage, large size and limited shape. To overcome these drawbacks and further expand the application fields, alternative pH sensor structures based on ion-sensitive field effect transistor (ISFET) [7][8][9], solid state [10,11], hydrogel [12,13], and microelectrode [14,15], have been reported.…”
Section: Introductionmentioning
confidence: 99%