2017
DOI: 10.1007/s00167-017-4823-0
|View full text |Cite
|
Sign up to set email alerts
|

Tibial internal rotation negatively affects clinical outcomes in total knee arthroplasty: a systematic review

Abstract: III.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

5
75
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 83 publications
(82 citation statements)
references
References 37 publications
5
75
0
2
Order By: Relevance
“…Unexplained pain after TKR, particularly in fixed bearing designs may be associated with component malrotation, 2 which is also associated with worse functional outcomes, 42,43 particularly in relation to tibial rotation. 44 The self-correcting characteristic of the rotating platform in rotation may be advantageous in this regard. The low rate of instability could be attributed to the gap-balancing approach in flexion and extension.…”
Section: Discussionmentioning
confidence: 99%
“…Unexplained pain after TKR, particularly in fixed bearing designs may be associated with component malrotation, 2 which is also associated with worse functional outcomes, 42,43 particularly in relation to tibial rotation. 44 The self-correcting characteristic of the rotating platform in rotation may be advantageous in this regard. The low rate of instability could be attributed to the gap-balancing approach in flexion and extension.…”
Section: Discussionmentioning
confidence: 99%
“…The knee score assesses pain, stability, and range of motion. 13 Although the effect of TKA component alignment on PROMs has been widely investigated in the current literature, 15,16 there are currently no studies that have investigated the potential relation between component alignment and PROMs in the contemporary BCR TKA design. Therefore, this study aims to determine: (1) accurate three-dimensional (3D) component alignment of BCR TKA and (2) whether the component alignment of BCR TKA affects patient-reported outcomes.…”
mentioning
confidence: 99%
“…Самым распространенным вариантом нарушения позиционирования компонентов оказа-лись ошибки в аксиальной плоскости. По данным различных исследований, значимыми считаются: внутренняя ротация только большеберцового компонента выше 5-6°, внутренняя ротация только бедренного компонента выше 4°, суммарная внутренняя ротация компонентов 6-10° и несоответствие ротационных положений компонентов от 5° [16,[28][29][30]. В соответствии с этими данными ошибки позиционирования компонентов в аксиальной плоскости были выявлены у 19 пациентов (24%).…”
Section: Discussionunclassified