Tilt-related alignment issues in miniature micromechanical on-wafer electrical probes composed of multiple flexible microcantilevers
Steve Arscott
Abstract:Some new issues concerning the contacting and positioning of small electrical microelectromechanical systems (MEMS) probes based on multiple, flexible microcantilevers are presented here. A tilt error, associated with the lateral probe roll, means that contact touchdown occurs sequentially in different cantilevers upon increasing probe overtravel. To understand the relationship between probe overtravel, tip skate, tip planarity, tip tangency, and contact force in the different contacts, the relationship betwee… Show more
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.