1990
DOI: 10.1007/bf02398398
|View full text |Cite
|
Sign up to set email alerts
|

Time dependence of the source recoilless fraction for a cobalt-57 in rhodium source

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1992
1992
2010
2010

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 1 publication
0
4
0
Order By: Relevance
“…(16) allows for non-Lorentzian primary radiation densities as well [24,25]. Actually single line spectra remain Lorentzian, albeit the line broadens with the increasing parameter β.…”
Section: Evaluation Of the Cem Spectra Originating In The Highly Enrimentioning
confidence: 99%
“…(16) allows for non-Lorentzian primary radiation densities as well [24,25]. Actually single line spectra remain Lorentzian, albeit the line broadens with the increasing parameter β.…”
Section: Evaluation Of the Cem Spectra Originating In The Highly Enrimentioning
confidence: 99%
“…Innovative courses based on project studies has helped many students to find self-discovery and opportunity for creativity in learning, Article on a personalized course in thermodynamics generated wide interest and promoted discussion about alternative approaches to teaching scientific material to students, Recent Research (Pub, , [41][42][43][44][45][46][47][48][49][50][51][52][53][54][55][56][57] Current research of J,G,M, centers on precision determination of the lineshape parameters in M6ssbauer effect (ME) spectroscopy, and the application of superintense ME sources to problems of elastic, quasl-elastic and inelastic scattering of the monochromatic recoilless photons from crystalline solids, The recent research investigations of J, Mullen can be broken into three major categories: lineshape measurements with M6ssbauer transmission and microfoil conversion electron (MICE) spectroscopy; scattering experiments using superintense ME sources to study charge density waves and anharmonic effects in crystals, and the study of the discontinuities in the internal fields for very precisely characterized magnetite,…”
Section: Innovation In Teaching: (Pub_6_7_33)mentioning
confidence: 99%
“…However, over the lifetime of a 57 Co source, the observed source recoilless fraction can change by more than 30%, changing the line shape and distorting the measurements of elastic scattering fraction. 15 By collecting full Mössbauer spectra, fitting them to the true line shape, and using sources only for a short period of time, we have eliminated these common sources of systematic error from our experiments.…”
Section: Introductionmentioning
confidence: 99%