2022
DOI: 10.1021/acs.analchem.2c04480
|View full text |Cite
|
Sign up to set email alerts
|

Time-Resolved Imaging of High Mass Proteins and Metastable Fragments Using Matrix-Assisted Laser Desorption/Ionization, Axial Time-of-Flight Mass Spectrometry, and TPX3CAM

Abstract: The Timepix (TPX) is a position-and time-sensitive pixelated charge detector that can be coupled with time-of-flight mass spectrometry (TOF MS) in combination with microchannel plates (MCPs) for the spatially and temporally resolved detection of biomolecules. Earlier generation TPX detectors used in previous studies were limited by a moderate time resolution (at best 10 ns) and single-stop detection for each pixel that hampered the detection of ions with high mass-to-charge (m/z) values at high pixel occupanci… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 59 publications
0
7
0
Order By: Relevance
“…Subsequently, the influence of the custom-built TOF analyzer and the associated ion optics on the ion trajectories was investigated by the visualization of the spatial distribution of the ion cloud with axial and orthogonal imaging detectors. The MCP-TPX quad ,, and MCP-P47-TPX3CAM ,, assemblies coupled with the Orbitrap/TOF instrument are deployed for this purpose (Configuration 1b, Figures S1–S2). Singly charged CsI ions of mass 5589 Da were selected using the quadrupole mass filter.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Subsequently, the influence of the custom-built TOF analyzer and the associated ion optics on the ion trajectories was investigated by the visualization of the spatial distribution of the ion cloud with axial and orthogonal imaging detectors. The MCP-TPX quad ,, and MCP-P47-TPX3CAM ,, assemblies coupled with the Orbitrap/TOF instrument are deployed for this purpose (Configuration 1b, Figures S1–S2). Singly charged CsI ions of mass 5589 Da were selected using the quadrupole mass filter.…”
Section: Resultsmentioning
confidence: 99%
“…The imaging assembly mounted on the orthogonal TOF MS consists of an MCP-P47-TPX3CAM detector system (Configurations 1b and 2) that was previously employed in Ultraflex III MS. 53 Briefly, each ion impact on the MCP-P47-TPX3CAM detection assembly leads to a cascade of secondary electrons within the MCP that is subsequently converted to photons by the scintillator (P47). The photons create local electron−hole pairs in the Si-coated TPX3 56 within the TPX3CAM that results in a detectable current on individual pixels of the TPX3 chip.…”
Section: ■ Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The imaging assembly mounted on the orthogonal TOF MS consists of an MCP-P47-TPX3CAM detector system that was previously employed in Ultraflex III MS. 322 Briefly, each ion impact on the MCP-P47-TPX3CAM detection assembly leads to a cascade of secondary electrons within the MCP that is subsequently converted to photons by the scintillator (P47). The photons create local electron-hole pairs in the Si-coated TPX3 137 within the TPX3CAM that results in a detectable current on individual pixels of the TPX3 chip.…”
Section: Tpx Detection Systemsmentioning
confidence: 99%
“…Here, we discuss the design and development of an innovative MS-based instrument that allows comprehensive molecular and structural analysis of MMAs at the same time using only picomoles of sample from solution. 320 A combination of a Thermo Scientific TM Q Exactive TM ultra-high mass range (UHMR) hybrid quadrupole-Orbitrap mass spectrometer 74,108,169,186,224 and a custom-designed orthogonal time-of-flight (TOF) mass analyzer, with an integrated 193 nm excimer laser [167][168][169]321 and two position-and-time sensitive Timepix (TPX) detectors 71,143,146,152,290,322 were used for the initial characterization of the system presented here. The Orbitrap/TOF system allows the m/z-resolved imaging of UV generated products from the precursor MMA ions, which can be utilized to understand the energetics of the MMA dissociation process as the TOF analyzer can retain the relative positions of the product ions following the fragmentation process until they reach the imaging detector.…”
Section: Introductionmentioning
confidence: 99%