Abstract:The selection of levels for tomographic sections of the kidneys during intravenous urography has previously been based on empirical observation. Three hundred abdominal computed tomographic scans were analyzed for the anteroposterior (AP) midpoints of the kidneys and their relationship to the patient's AP abdominal diameter. A graph for selection of tomographic levels was generated and compared with existing methods. These guidelines enable a more objective approach to urographic tomography.
“…We use the following formula to determine our preliminary tomographic level (11)(12)(13): (anteroposterior abdominal diameter [cm] ϫ 1 ⁄2) Ϫ 2 cm. We use the following formula to determine our preliminary tomographic level (11)(12)(13): (anteroposterior abdominal diameter [cm] ϫ 1 ⁄2) Ϫ 2 cm.…”
Section: Standard Procedures For Intravenous Urographymentioning
“…We use the following formula to determine our preliminary tomographic level (11)(12)(13): (anteroposterior abdominal diameter [cm] ϫ 1 ⁄2) Ϫ 2 cm. We use the following formula to determine our preliminary tomographic level (11)(12)(13): (anteroposterior abdominal diameter [cm] ϫ 1 ⁄2) Ϫ 2 cm.…”
Section: Standard Procedures For Intravenous Urographymentioning
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.