2001
DOI: 10.1054/arth.2001.21498
|View full text |Cite
|
Sign up to set email alerts
|

Total knee arthroplasty using the S-ROM mobile-bearing hinge prosthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
28
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 72 publications
(29 citation statements)
references
References 48 publications
1
28
0
Order By: Relevance
“…Options have included the use of impaction bone-grafting [22,25,38,40,44], structural bulk allografts [7,11,14,16,17,28,31,39], and tumor-type megaprostheses [2]. Studies with structural allografts and tumor megaprostheses during revision knee arthroplasty have reported encouraging mid-term results, but the high number of complications is a concern.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Options have included the use of impaction bone-grafting [22,25,38,40,44], structural bulk allografts [7,11,14,16,17,28,31,39], and tumor-type megaprostheses [2]. Studies with structural allografts and tumor megaprostheses during revision knee arthroplasty have reported encouraging mid-term results, but the high number of complications is a concern.…”
Section: Discussionmentioning
confidence: 99%
“…Major tibial and femoral bone defects, classified as Anderson Orthopaedic Research Institute (AORI) [10] Types 2B and 3, have been reconstructed using impaction bone grafting with or without mesh augmentation [22,25,38,40,44], structural or bulk allografts [7,11,14,16,17,28,31,39], modular metal augmentations of prostheses [15,32], and tumor-type megaprostheses [2]. Studies using structural allografts have reported numerous complications and minimum 5-year survivorship of 67% to 96% [1,6,7,14,17], whereas reconstructions with tumor-type megaprostheses have shown a 5-year survivorship of 68% [33].…”
Section: Introductionmentioning
confidence: 99%
“…5,11,20 In revisions of hinges, the use of highly constrained implants, rotating hinges, fixed-axis hinges, or segmental knee replacements poses the problem that poor bone stock is exposed to increased loading by the highly constrained articulation of the revision implants. 13,15,18,23,26 As a result, implant loosening and bone fracture (Table 1) occur. 1,13,15 Another specific complication is failure of the extensor mechanism.…”
mentioning
confidence: 99%
“…13,15,18,23,26 As a result, implant loosening and bone fracture (Table 1) occur. 1,13,15 Another specific complication is failure of the extensor mechanism. 1,15 To solve this problem, nonhinged total condylar prostheses with rotating platform PE inserts and short intramedullary stems were used in this series.…”
mentioning
confidence: 99%
See 1 more Smart Citation