2023
DOI: 10.1109/jsen.2023.3242318
|View full text |Cite
|
Sign up to set email alerts
|

Toward Planar Atomic-Gold Decorated Polyaniline Gas Sensors for Enhanced Electrochemical Sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(11 citation statements)
references
References 28 publications
0
11
0
Order By: Relevance
“…PANI and PANI doped with ZnO have affinity towards various volatile substances, such as methanol, isopropanol, and benzyl alcohol 36 38 . Isopropanol was chosen as the test vapor due to its widespread use in pharmaceuticals, cosmetics, and cleaning products, making it readily available and good representative of volatile organic gases.…”
Section: Methodsmentioning
confidence: 99%
“…PANI and PANI doped with ZnO have affinity towards various volatile substances, such as methanol, isopropanol, and benzyl alcohol 36 38 . Isopropanol was chosen as the test vapor due to its widespread use in pharmaceuticals, cosmetics, and cleaning products, making it readily available and good representative of volatile organic gases.…”
Section: Methodsmentioning
confidence: 99%
“…Afterward, the modified Pt/PANI electrode was installed in the chamber where its two WEs and CE were connected to the line of WE and CE at potentiostat, respectively (the potentiostat was based on IC TL074, Texas Instruments, Dallas, TX, USA); since the RE from IDA made of Pt, hence, external Ag/AgCl was used as RE to maintain the stable EC reaction during the gold deposition process which connected to the RE line at potentiostat. Furthermore, the timing diagram of the deposition process to fabricate the Au2 clusters is shown in Figure 2b [32][33][34][35], and modified Pt/PANI/Au2 using IDA electrode is described in Figure 2c.…”
Section: Atomic Gold Depositionmentioning
confidence: 99%
“…Afterward, the modified Pt/PANI electrode was installed in the chamber where its two WEs and CE were connected to the line of WE and CE at potentiostat, respectively (the potentiostat was based on IC TL074, Texas Instruments, Dallas, TX, USA); since the RE from IDA made of Pt, hence, external Ag/AgCl was used as RE to maintain the stable EC reaction during the gold deposition process which connected to the RE line at potentiostat. Furthermore, the timing diagram of the deposition process to fabricate the Au 2 clusters is shown in Figure 2b [32][33][34][35], and modified Pt/PANI/Au 2 using IDA electrode is described in Figure 2c. Since the current commercial SEM technology is not able to be used to confirm the presence of atomic gold in PANI due to the resolution limits, the alternative way to confirm the Au 2 clusters, which have also been massively reported and applied, has been using the information of oxidation from propanol isomers in the alkaline medium [15,19,26,[32][33][34].…”
Section: Atomic Gold Depositionmentioning
confidence: 99%
See 1 more Smart Citation
“…Currently, the common detection methods for gas contain chemical methods and spectroscopic methods. Chemical methods include electrochemical sensors, chemiluminescent detectors (CLD), gas chromatography (GC), and chemiresistive gas sensors. Among these, the electrochemical sensor is susceptible to other substances in exhaled breath (EB) with a short service life and high maintenance costs. While the CLD is highly sensitive to trace NO gas, it usually requires the use of excessive amounts of a toxic reagent (O 3 ), thereby causing frequent maintenance and calibration.…”
mentioning
confidence: 99%