Computers in Cardiology, 2005 2005
DOI: 10.1109/cic.2005.1588077
|View full text |Cite
|
Sign up to set email alerts
|

Towards automatic full heart segmentation in computed-tomography images

Abstract: We present a robust, fast and fully automatic approach enabling the segmentation of the main anatomical structures of the heart in CT images. The proposed method is based on the adaptation of a 3D triangulated mesh to new unknown images exploiting simultaneously knowledge of organ shape and typical gray level appearance in images, both learned from a training database made of 28 data sets. The described approach was tested on more than 50 volume images at different cardiac phases. Visual inspection by experts … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
1

Year Published

2006
2006
2020
2020

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 8 publications
0
10
0
1
Order By: Relevance
“…the initial phase image has to be replaced by a fully automatic method. 22 The overall results show, that the new automatic tracking method is able to replace the semi-automatic short axis method with a good correlation of results in the assessment of left ventricular function from retrospective ECG-gated cardiac multi-slice computed tomography image series.…”
Section: Resultsmentioning
confidence: 89%
See 1 more Smart Citation
“…the initial phase image has to be replaced by a fully automatic method. 22 The overall results show, that the new automatic tracking method is able to replace the semi-automatic short axis method with a good correlation of results in the assessment of left ventricular function from retrospective ECG-gated cardiac multi-slice computed tomography image series.…”
Section: Resultsmentioning
confidence: 89%
“…A sparse sampling by ray-casting has been proposed in 21 and was successfully used to quickly determine the human heart centre. 22 Also an affine pre-registration by a set of anatomical landmarks is suitable, 23, 24 but requires manual or automatic localization of these landmarks. We decided in order for the shape tracking method to have an optimal and approved initialization to semi-automatically adapt the model to the initial end-diastolic phase image.…”
Section: Pose and Pre-registrationmentioning
confidence: 99%
“…The surfaces may be also automatically deformed to fit the respective image boundaries. The application of the surface model for fully automatic cardiac analysis is currently employed [4]. In addition to the end-diastolic shape model, a mean cardiac motion model was created on the basis of 11 multi-phase data sets.…”
Section: Discussionmentioning
confidence: 99%
“…However, there is also a need to segment the heart as a whole in order to distinguish its limits and the separations with surrounding structures such as the liver or the aorta. The existing methods for segmenting the heart have been focused on MRI modality [5,[7][8][9][10][11] or ultrasound [6,12] but rarely on CT [13][14][15][16]. However, for the aforementioned applications, CT is one of the most common anatomical imaging modalities.…”
Section: Related Workmentioning
confidence: 99%
“…The work by Ecabert et al [15,16] describes a multi-compartment mesh of both atria, both ventricles, the myocardium around the left ventricle and the trunks of the great vessels and it is adapted to an image volume. The adaptation is performed in a coarse-to-fine manner by progressively relaxing constraints on the degrees of freedom of the allowed deformations.…”
Section: Related Workmentioning
confidence: 99%