2011
DOI: 10.1039/c1ay05115f
|View full text |Cite
|
Sign up to set email alerts
|

Trace beryllium determination in polyvinyl alcohol wipes by extraction and fluorescence detection: interlaboratory analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…The chemical analysis of such dissolution using flame-based optical spectrometry indicated the 70 content of each REE label on the testing area. 41 This procedure is used by organizations such as the OSHA 42 in studies of exposure levels and threshold limit values for different metals. In our case, we have monitored the concentration of the lanthanide labels.…”
Section: Analytical Determination Of the Deposited Mass Of Nanoparticlesmentioning
confidence: 99%
“…The chemical analysis of such dissolution using flame-based optical spectrometry indicated the 70 content of each REE label on the testing area. 41 This procedure is used by organizations such as the OSHA 42 in studies of exposure levels and threshold limit values for different metals. In our case, we have monitored the concentration of the lanthanide labels.…”
Section: Analytical Determination Of the Deposited Mass Of Nanoparticlesmentioning
confidence: 99%
“…Several standard methods have been promulgated that utilize these reagents. 11,14,27,[34][35][36][37][38][39] Based on the data analysis of this work, the interlaboratory data also show conclusively that sample preparation using nitric acid alone, or combinations of nitric and hydrochloric acids, is not effective for complete extraction of Be from high-fired BeO. It is noted that the use of HNO 3 alone or in combination with HCl or HClO 4 may be suitable for dissolving Be from some matrices, but the results herein indicate that HNO 3 should not be the sole or primary acid employed when the sample is expected to contain refractory BeO.…”
Section: Discussionmentioning
confidence: 99%
“…Further interlaboratory evaluations were proposed and this reviewer recommends, if possible, the use of real matrix samples to assess the performance of the key digestion step. Ashley et al 80 also undertook an intercomparison exercise to ascertain the performance of a field-based fluorescence method for the determination of trace levels of Be in polyvinyl alcohol wipes used in surface swabbing monitoring exercises. Test wipes were spiked with a BeO CRM material to provide spiking levels in the range 0.03 to 5.6 mg Be/wipe.…”
Section: Sample Preparationmentioning
confidence: 99%