2020
DOI: 10.1515/cclm-2020-0015
|View full text |Cite
|
Sign up to set email alerts
|

Traceability validation of six enzyme measurements on the Abbott Alinity c analytical system

Abstract: AbstractBackgroundLaboratory professionals should independently verify the correct implementation of metrological traceability of commercial measuring systems and determine if their performance is fit for purpose. We evaluated the trueness, uncertainty of measurements, and transferability of six clinically important enzyme measurements (alanine aminotransferase [ALT], alkaline phosphatase… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 34 publications
0
5
0
Order By: Relevance
“…According to the PRORATA trial [17], in ICU patients with lower respiratory tract infections, PCT values <0.25 μg/L indicate bacterial etiology as very unlikely, while values ≥1.0 μg/L indicate a high probability for this etiology. CRP, serum albumin, and LDH were determined on the Alinity c platform (Abbott Diagnostics) by using immunoturbidimetry (CRP and albumin) and enzymatic (LDH) assays [18][19][20]. The mean CVs in the study period were 3.1% for CRP, 1.8% for albumin, and 1.2% for LDH, at a mean analyte concentration of 12.0 mg/L (CRP), 39.6 g/L (albumin), and 395 U/L (LDH), respectively.…”
Section: Methodsmentioning
confidence: 99%
“…According to the PRORATA trial [17], in ICU patients with lower respiratory tract infections, PCT values <0.25 μg/L indicate bacterial etiology as very unlikely, while values ≥1.0 μg/L indicate a high probability for this etiology. CRP, serum albumin, and LDH were determined on the Alinity c platform (Abbott Diagnostics) by using immunoturbidimetry (CRP and albumin) and enzymatic (LDH) assays [18][19][20]. The mean CVs in the study period were 3.1% for CRP, 1.8% for albumin, and 1.2% for LDH, at a mean analyte concentration of 12.0 mg/L (CRP), 39.6 g/L (albumin), and 395 U/L (LDH), respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The liver is a metabolic organ in the body and plays a role to oxidize, store glycogen and secrete proteins [ 30 ]. The liver also produces bile in the digestive system [ 31 ].…”
Section: Resultsmentioning
confidence: 99%
“…Aloisio et al 23 suggested that laboratory professionals should independently verify the correct implementation of metrological traceability of measuring systems. The EQA/PT scheme not only plays an important role in evaluating the performance of each laboratory but also has unique efficacy in monitoring the equivalence of measurement results and the success of standardization 24 .…”
Section: Discussionmentioning
confidence: 99%