2003
DOI: 10.1093/bja/aeg560
|View full text |Cite
|
Sign up to set email alerts
|

Tracheal intubation using a Macintosh laryngoscope or a GlideScope ® in 15 patients with cervical spine immobilization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
67
0
2

Year Published

2005
2005
2014
2014

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 142 publications
(71 citation statements)
references
References 5 publications
2
67
0
2
Order By: Relevance
“…We believe that using a stylet and correctly shaping the tracheal tube is mandatory to assist tracheal intubation with the McGrath®, as with other videolaryngoscopes. 3,5,10,12,13 The rigidity of the stylet also seems to be important -we have found that a thicker, more rigid stylet makes tracheal intubation easier.…”
Section: Discussionmentioning
confidence: 88%
See 1 more Smart Citation
“…We believe that using a stylet and correctly shaping the tracheal tube is mandatory to assist tracheal intubation with the McGrath®, as with other videolaryngoscopes. 3,5,10,12,13 The rigidity of the stylet also seems to be important -we have found that a thicker, more rigid stylet makes tracheal intubation easier.…”
Section: Discussionmentioning
confidence: 88%
“…8,9 Until recently, three videolaryngoscopes have been commercially available -the Glidescope® (Saturn Biomedical Inc, Burnaby, BC, Canada), the Macintosh VideoLaryngoscope (Karl Storz GmBH and Co., Tuttlingen, Germany) and the X-lite® (Rusch Inc., Tuttlingen, Germany). Use of the Glidescope® has been most extensively reported, [1][2][3][4][5][8][9][10][11][12][13][14][15][16][17][18][19][20][21][22] and the Macintosh VideoLaryngoscope has been described recently. 23 Successful use of the X-lite® has also been reported 24 but this device is no longer produced.…”
Section: Résultats : Le Taux De Réussite Des Intubations Trachéales Pmentioning
confidence: 99%
“…Numerous reports of the use of indirect laryngoscopic devices in patients with known, suspected or simulated cervical spine pathology have been published [46,[48][49][50][51].…”
Section: Choice Of New Intubation Equipmentmentioning
confidence: 99%
“…For example, due to cervical spine immobilization, the intubating laryngeal mask (ILMA)® (LMA Deutschland GmbH, Bonn, Germany) allows blind insertion of an endotracheal tube, 2 while the Trachlight® stylet (Laerdal Medical Co., Wappingers Falls, NY, USA) facilitates intubation based upon the principle of transillumination of the soft tissues of the neck. 3,4 Devices which apply the principle of indirect visualization of the laryngeal structures include the GlideScope® (Verathon Inc., Bothell, WA, USA), a video laryngoscope with a digital camera located at the blade tip, and a small, separate LCD-monitor connected to the laryngoscope handle with a short cable. 3,4 The rigid Bonfils® intubation fibrescope (Karl Storz GmbH and Co. KG, Tuttlingen, Germany), 5 which has been shown to be effective for difficult airway management, 6 allows visualization of the glottic aperture and the trachea, and thus endotracheal tube placement under vision.…”
mentioning
confidence: 99%
“…3,4 Devices which apply the principle of indirect visualization of the laryngeal structures include the GlideScope® (Verathon Inc., Bothell, WA, USA), a video laryngoscope with a digital camera located at the blade tip, and a small, separate LCD-monitor connected to the laryngoscope handle with a short cable. 3,4 The rigid Bonfils® intubation fibrescope (Karl Storz GmbH and Co. KG, Tuttlingen, Germany), 5 which has been shown to be effective for difficult airway management, 6 allows visualization of the glottic aperture and the trachea, and thus endotracheal tube placement under vision. Although the efficacy of the Bonfils intubation fibrescope has been demonstrated in patients with anticipated difficult airway based on predictors, 7 its use has not been prospectively evaluated in patients with documented difficult airways.…”
mentioning
confidence: 99%