2017
DOI: 10.1021/acs.nanolett.7b01676
|View full text |Cite
|
Sign up to set email alerts
|

Tracking Nanoelectrochemistry Using Individual Plasmonic Nanocavities

Abstract: We study in real time the optical response of individual plasmonic nanoparticles on a mirror, utilized as electrodes in an electrochemical cell when a voltage is applied. In this geometry, Au nanoparticles are separated from a bulk Au film by an ultrathin molecular spacer. The nanoscale plasmonic hotspot underneath the nanoparticles locally reveals the modified charge on the Au surface and changes in the polarizability of the molecular spacer. Dark-field and Raman spectroscopy performed on the same nanoparticl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
55
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 44 publications
(61 citation statements)
references
References 28 publications
5
55
0
Order By: Relevance
“…It should be noted that the electric and magnetic field enhancement is strongly dependent on the NP diameter at fixed wavelength (Figure a, b), providing maxima values at the NP diameters of ∼160, 190, 240, and 280 nm. These numerical results correlate with experiment on light scattering by such NPs in dark field geometry (see Supporting Information, Figure S3), where the intrinsic NP optical resonances and pump/scattering are merged …”
Section: Resultssupporting
confidence: 81%
See 4 more Smart Citations
“…It should be noted that the electric and magnetic field enhancement is strongly dependent on the NP diameter at fixed wavelength (Figure a, b), providing maxima values at the NP diameters of ∼160, 190, 240, and 280 nm. These numerical results correlate with experiment on light scattering by such NPs in dark field geometry (see Supporting Information, Figure S3), where the intrinsic NP optical resonances and pump/scattering are merged …”
Section: Resultssupporting
confidence: 81%
“…Despite high thermal stability of dielectrics within broad temperature range, applicability of such nanoscale Raman thermometers for the most of chemical and biological processes is hindered by relatively long data acquisition time (hundreds of second for commercial Raman spectrometers), which is due to low RS signal intensity from non‐resonant nanometer scale objects.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations