Proceedings 1995 International Conference on Energy Management and Power Delivery EMPD '95
DOI: 10.1109/empd.1995.500762
|View full text |Cite
|
Sign up to set email alerts
|

Transformer testing and analysis with a Window-based graphic user interface

Abstract: An on-line testing and analysis prototype, called TXWIN, for distribution power transformers is presented in this paper. TXWIN allows the user to perform no-load test, load-loss test, and ratio test automatically via Windows Graphic User Interfaces (GUI). It also contains other transformer performance tests: DC resistance measurement test, high tension test, and insulation test. The prototype also has the functions to analyze test results, generate customized reports, and store transformer data in database.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0
1

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
2
0
1
Order By: Relevance
“…The TTR tests aims to diagnose the transformer over its winding (primary and / or secondary), where it is checked the relationship between the turns of the high-voltage and lowvoltage transformer under analysis [10].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The TTR tests aims to diagnose the transformer over its winding (primary and / or secondary), where it is checked the relationship between the turns of the high-voltage and lowvoltage transformer under analysis [10].…”
Section: Introductionmentioning
confidence: 99%
“…These approaches are mainly centered in: DGA [5][6][7][8][9], TTR [10] and induced voltage tests [11][12].…”
Section: Introductionmentioning
confidence: 99%
“…novo transformador como à manutenção do mesmo. Por meio da análise da literatura correlata, pode-se verificar e destacar alguns métodos de ensaio de transformadores de transmissão visando à detecção de falhas, a saber: análise dos gases dissolvidos no óleo isolante[28][29][30][31][32], ensaios de relação de espiras[33] e ensaios de tensão induzida[34][35].As abordagens de detecção de falhas em transformadores por meio da análise da concentração dos gases dissolvidos no óleo isolante do equipamento baseiam-se na constatação de que as falhas, tais como as descargas parciais, as descargas de alta energia, os efeitos corona, Os ensaios de relação de espiras têm por objetivo diagnosticar o transformador em relação ao seu enrolamento (primário e/ou secundário), onde é verificada a relação entre as espiras do lado de alta e baixa tensão do transformador sob análise. Já os ensaios de tensão induzida são empregados quando da necessidade de se realizar testes dielétricos (em campo) nos transformadores de potência.…”
unclassified